Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

نویسندگان

  • Ali Soleimani Meigooni PhD, Comprehensive Cancer Centers of Nevada, Las Vegas, NV, USA
  • Amir Mehdizadeh MSc, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • Reza Faghihi PhD, School of Mechanical Engineering, Shiraz University, Shiraz, Iran PhD, Radiation Research Center, Shiraz University, Shiraz, Iran
  • Sedigheh Sina PhD, School of Mechanical Engineering, Shiraz University, Shiraz, Iran PhD, Radiation Research Center, Shiraz University, Shiraz, Iran
چکیده مقاله:

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 192Ir source model mHDR-v2r, and BEBIG 60Co source model Co0.A86 was used. The TG-43 formalism was used to calculate the treatment time required for both radionuclides. The reference absorbed doses to points A and B were determined from treatment data of an adult patient treated in a cancer center using Tandem- ovoid applicator, and 192Ir source. The treatment data provide us with the exact dwell positions, and times of the source, and positions of the dosimetry points. The absorbed dose to points A and B were calculated with TG-43 formalism using treatment data for iridium source, then the calculated absorbed doses were compared with absorbed doses in treatment data to determine the accuracy of using TG-43 formalism. The treatment time for iridium source is calculated by using absorbed dose in treatment data and the TG43 formalism. Then, the calculations were performed for 60Co. Considering the absorbed dose in reference points, and using the TG-43 formalism, the treatment time for cobalt source is calculated. Finally, the treatment time obtained for the two sources are compared with each other. Results: The results of this study indicate that the treatment time for cobalt source with a specific activity of 2.131 Ci is almost the same as the treatment time for iridium source with the specific activity of 5.690 Ci. For a treatment duration of 16 minutes, the effective time window for 192Ir is about 1 to 160 days, while for 60Co this time window becomes 2000 days. Conclusion: According to the results obtained in this study, using16 minutes treatment time60Co instead of 192Ir will be beneficial in treatment of cervical cancer patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

Comparison of 60Co and 192Ir sources in HDR brachytherapy

This paper compares the isotopes (60)Co and (192)Ir as radiation sources for high-dose-rate (HDR) afterloading brachytherapy. The smaller size of (192)Ir sources made it the preferred radionuclide for temporary brachytherapy treatments. Recently also (60)Co sources have been made available with identical geometrical dimensions. This paper compares the characteristics of both nuclides in differe...

متن کامل

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

comparison of catalytic activity of heteropoly compounds in the synthesis of bis(indolyl)alkanes.

heteropoly acids (hpa) and their salts have advantages as catalysts which make them both economically and environmentally attractive, strong br?nsted acidity, exhibiting fast reversible multi-electron redox transformations under rather mild conditions, very high solubility in polar solvents, fairly high thermal stability in the solid states, and efficient oxidizing ability, so that they are imp...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  216- 216

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023