Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
نویسندگان
چکیده مقاله:
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared. Material & Methods: In this cross-sectional study, we assessed the tracheal tube cuff inflation pressure among 80 anesthesiologists, nurses of anesthesia, and anesthesiology assistants using a manometer. High-volume, low-pressure tubes were used for intubation in all patients. The anesthesiologists and other personnel were not informed of the planned study. Results: The average pressure generated by inflating the endotracheal tube cuff among anesthesiologists and senior anesthesia assistants, junior nurses with 1 to 15 years of experience in anesthesia, senior nurses with 15-30 years of experience in anesthesia and, junior anesthesia assistants were 49.24±24, 70.8±29, 56.8±20 and 73.5±29 mmHg, respectively. Conclusion: There is a tendency to over inflation of endotracheal tube cuffs in all anesthesia team. Palpation in order to assess the adequacy of cuff inflation is not sufficient and anesthesia providers should consider using devices such as manometers to facilitate safe inflation and accurate measurement of endotracheal tube cuff pressure.
منابع مشابه
Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation
Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC's balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in the present study, we tried to evaluate the most two common fixed volume and pilot balloon palpita...
متن کاملMaintenance of tracheal tube cuff pressure: where are the limits?
Continuous control of tracheal tube cuff inflation using a pneumatic device resulted in severe tracheal wall damage in ventilated piglets. This damage was similar in piglets managed with manual control of cuff inflation. The periodic hyperinflation of the tube cuff used in both groups of this study may explain these results. This manoeuvre should be avoided in clinical practice.
متن کاملStudy of endotracheal tube cuff pressure and time of measurement among intensive care units patients
Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...
متن کاملبررسی میزان فشار کاف لوله تراشه و عوامل مرتبط با آن در بیماران تحت بیهوشی عمومی در اتاق عمل مرکز آموزشی درمانی امام خمینی(ره) ساری، سال 1388
Background and purpose: The cuff of tracheal tube is important and secures the airway during anaesthesia. This study evaluates the effect of endotracheal tube cuff pressure after tracheal intubation during general anesthesia. Materials and methods: This is a descriptive observational study that recruits 500 ÂSÂ physical status Ï and ÏÏ patients undergoing elective surgery under general anaes...
متن کامل[Effects of tracheal tube cuff limit pressure (25 cmH2O) and "seal" pressure on tracheal mucosa of dogs.].
BACKGROUND AND OBJECTIVES Injuries of tracheal mucosa in contact with tracheal tube cuff is a function of cuff pressure and exposure time. This study aimed at analyzing injuries of tracheal mucosa in contact with tracheal tube cuff inflated to reach "seal" pressure or limit 25 cmH2O pressure, below critical 30 cmH2O, to prevent tracheal damage. METHODS This study involved 16 dogs submitted to...
متن کاملTracheal tube cuff inflation as an aid to blind nasotracheal intubation.
We have assessed the efficacy of tracheal tube cuff inflation in the oropharynx as an aid to blind nasotracheal intubation in 20 ASA I and II patients undergoing elective oral surgery. The trachea was intubated once using the technique of tracheal tube cuff inflation in the oropharynx and once keeping the tracheal tube cuff deflated throughout the manoeuvre. With the cuff deflated, intubation w...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 4 شماره 3
صفحات 14- 24
تاریخ انتشار 2019-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023