Comparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates
نویسندگان
چکیده مقاله:
Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled clinical trial was conducted on 119 neonates diagnosed with RDS, with the gestational age of 28-34 weeks and birth weight of 1000-2200 grams, who were admitted in the neonatal intensive care unit (NICU). Infants were allocated to two groups of ventilator CPAP (VCPAP) and bubble CPAP (BCPAP) therapy. Results: Mean weight, gestational age, and one-minute Apgar score were not significantly different between the two groups. However, duration of treatment with mechanical ventilation in the BCPAP group was significantly lower compared to the VCPAP group. In addition, frequency of complications had no significant difference between the two groups. Conclusion: In the treatment of RDS, duration of mechanical ventilation was lower in the BCPAP group compared to the VCPAP group in premature neonates
منابع مشابه
Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates
Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...
متن کاملBubble CPAP for respiratory distress syndrome in preterm infants.
OBJECTIVES To ascertain the immediate outcome of preterm infants with respiratory distress syndrome (RDS) on Bubble CPAP and identify risk factors associated with its failure. STUDY DESIGN Prospective analytical study. SUBJECTS Inborn preterm infants (gestation 28 to 34 weeks) admitted to the NICU with respiratory distress and chest X ray suggestive of RDS. INTERVENTION Bubble CPAP with b...
متن کاملBubble–CPAP vs. Ventilatory–CPAP in Preterm Infants with Respiratory Distress
OBJECTIVE Application of Continuous Positive Airway Pressure (CPAP) in neonate with respiratory distress is associated with reduction of respiratory failure, reduced complications and mortality. Bubble CPAP (B-CPAP) and ventilator-derived CPAP (V-CPAP) are two most popular CPAP modes. We aimed to determine whether B-CPAP and V-CPAP would have different survival rate and possible complications. ...
متن کاملBubble CPAP versus CPAP with variable flow in newborns with respiratory distress: a randomized controlled trial.
OBJECTIVE To evaluate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) using devices with variable flow or bubble continuous positive airway pressure (CPAP) regarding CPAP failure, presence of air leaks, total CPAP and oxygen time, and length of intensive care unit and hospital stay in neonates with moderate respiratory distress (RD) and birth weight (BW) ≥ 1,500 g. ...
متن کاملBubble CPAP - a primary respiratory support for respiratory distress syndrome in newborns.
In preterm infants with respiratory distress syndrome (RDS), the application of continuous positive airway pressure (CPAP) is associated with benefits in terms of reduced respiratory failure and reduced mortality. We conducted this prospective study to evaluate the effectiveness of bubble-CPAP as primary mode of respiratory support. Bubble CPAP was found to be safe and effective means of treati...
متن کاملThe Use of Bubble CPAP in Premature Infants: Local Experience
Received February 15, 2007 Abstract Bubble continuous positive airway pressure (CPAP) was introduced more than 30 years ago for infants with respiratory distress. With this, there had been reports of decreased incidence of mechanical ventilation and chronic lung disease among the premature, as well as less failure of extubation. This report described how this treatment modality was adopted loca...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 8 شماره 3
صفحات 1- 5
تاریخ انتشار 2017-09-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023