Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems
نویسندگان
چکیده مقاله:
Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instrument for root canal therapy is difficult. The aim of this study was to compare the maintenance of working length and original shape of curved canals and the incidence of procedural errors, using the newly introduced Race and the older Flexmaster rotary systems. Materials and Methods: In this experimental study, 40 resin blocks with a 45° curvature were randomly divided into two groups. After determination of the working length and staining with methylen blue, photographs were obtained. All root canals were prepared using Flexmaster and Race rotary systems according to the manufacturers’ insructions. The working lengths were determined once more and the prepared canals were stained with Eosin and photographs were taken. Pre- and post-preparation images were superimposed and changes in the canal walls were evaluated. Data were analyzed using Mann-Whitnney and student t-tests. Results: The mean canal transportation (determined from the inner and outer width measurements) was higher for Race as compared to Flexmaster. The mean loss of working length in the Race (0/54mm) and Flexmaster groups (0/59 mm) was similar. The incidence of zips and elbows was %20 and %35 in the Race and Flexmaster groups, respectively. Conclusion: Based on the results of this study, Race instruments produce more changes in the anatomy of severely curved simulated root canals, as compared to Flexmaster instruments. Key words: Curved resin blocks - Rotary system – Flexmaster – Race.
منابع مشابه
comparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولcomparison of canal preparation pattern of k3 and protaper rotary files in curved resin blocks
introduction: the purpose of this study was to evaluate and compare canal preparation pattern of k3 and protaper rotary files in curved resin blocks. materials and methods: twenty-four resin blocks were used in this experimental study and randomly divided into two groups. their initial images were scanned. after preparation, their images were scanned again in the same position. pre and post pre...
متن کاملComparison of Canal Preparation Pattern of K3 and ProTaper Rotary Files in Curved Resin Blocks
INTRODUCTION The purpose of this study was to evaluate and compare canal preparation pattern of K3 and ProTaper rotary files in curved resin blocks. MATERIALS AND METHODS Twenty-four resin blocks were used in this experimental study and randomly divided into two groups. Their initial images were scanned. After preparation, their images were scanned again in the same position. Pre and post pre...
متن کاملComparison of the shaping ability of RaCe, FlexMaster, and ProFile nickel-titanium instruments in severely curved root canals
BACKGROUND This in vitro study compared the shaping ability of RaCe, FlexMaster, and ProFile rotary nickel-titanium instruments in severely curved root canals of extracted teeth. MATERIAL AND METHODS Sixty maxillary molars with curvatures ranging from 25° to 65° were embedded in a muffle system and portioned into five horizontal sections (thickness 1.2 mm), starting from the apex. Canals were...
متن کاملin vitro comparison of apical debris extrusion using rotary and reciprocating systems in severely curved root canals
introduction: the aim of this in vitro study was to compare the amount of apically extruded debris after root canal preparation using rotary and reciprocating systems in severely curved root canals. methods and materials: thirty six extracted human mandibular first molars with 25-35 ° curvature in their mesiobuccal (mb) canal (according to schneider’s method) were cleaned and shaped with protap...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 18 شماره 3
صفحات 0- 0
تاریخ انتشار 2006-06