Comparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer

نویسندگان

  • Ali Akhavan Department of Radiation Oncology, Seyed Al-Shohada Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
  • Iraj Jabbari Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, Iran
  • Mohsen Saeb Department of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran
  • Pardis Ghaffarian PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Shahram Monadi Department of Radiation Oncology, Seyed Al-Shohada Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
  • Yasmin Yaraghi Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, Iran
چکیده مقاله:

Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for image fusion, contouring and radiation treatment planning. For each patient two separate gross tumor volumes were delineated based on CT and PET/CT images as GTVCT and GTVPET/CT, respectively. In addition, three different indices including conformity index (CI), geographic miss index (GMI) and geographic include index (GII) were calculated to quantify the match and mismatches degree between derived volumes. Then, for each patient an appropriate 3D conformal treatment plan was made based on the PTVCT and then these plans were applied on the PTVPET/CT. Afterwards, the dose coverage of PTVPET/CT was estimated through several dosimetric parameters. Results:The GTVPET/CT was larger than GTVCT for majority of cases. The 25% exceeded volumetric alterations were observed in 8 of all cases (40%). Mean values of CI, GMI and GII were 0.43, 0.42 and 0.34, respectively. Also, dosimetric parameters indicated inadequate dose coverage of PTVPET/CT in CT-based RT plans for most of the patients. Conclusion: Incorporating PET data into tumor delineation process had a great potential to improve the quality of radiation treatment planning for NSCLC.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance

this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...

15 صفحه اول

the effects of time planning and task complexity on accuracy of narrative task performance

هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...

Anticancer and Apoptotic Effects of Ectoine and Hydroxyectoine on Non-Small Cell Lung Cancer cells: An in-vitro Investigation

Introduction: Streptomyces manage the osmotic stress by collecting compatible solutes or osmolytes. Ectoine, 1,4,5,6-tetrahydro-2-methyl-4-pyrimidine carboxylic acid, and 5-hydroxyectoine are among the most common osmolytes of this bacteria and have an active role in protecting the genetic material of this microorganism as well as providing resistance to environmental pressures. In this researc...

متن کامل

Anticancer and Apoptotic Effects of Ectoine and Hydroxyectoine on Non-Small Cell Lung Cancer cells: An in-vitro Investigation

Introduction: Streptomyces manage the osmotic stress by collecting compatible solutes or osmolytes. Ectoine, 1,4,5,6-tetrahydro-2-methyl-4-pyrimidine carboxylic acid, and 5-hydroxyectoine are among the most common osmolytes of this bacteria and have an active role in protecting the genetic material of this microorganism as well as providing resistance to environmental pressures. In this researc...

متن کامل

the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine

abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 1

صفحات  9- 15

تاریخ انتشار 2018-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023