Comparison of patient-collected and lab technician-collected nasopharyngeal and oropharyngeal swabs for detection of COVID-19 by RT-PCR
نویسندگان
چکیده مقاله:
Background & Objective: A simple approach to prevent close contact in healthcare settings during the COVID-19 outbreak is to train patients to collect their own nasopharyngeal and oropharyngeal swabs and deliver them to medical laboratories to have them processed. The aim of our study was to compare lab technician- with patient- collected oropharyngeal and nasopharyngeal samples for detection of the coronavirus disease 2019 (COVID 19) using rapid real-time polymerase chain reaction (rRT-PCR). Methods: Fifty adult patients with flu-like symptoms and radiologic findings compatible with atypical pneumonia who were admitted to the infectious diseases ward of Imam Khomeini Hospital Complex, Tehran, Iran, with a clinical diagnosis of COVID-19 from February 28 to April 27 of 2020 were randomly selected and entered in our study. Two sets of naso- and oropharyngeal swabs were collected, one set by a lab technician and the other by the patients, and the COVID-19 rRT-PCR test was performed. Results: Of 50 selected cases, in seven patients all collected naso- and oropharyngeal swabs tested positive, and in 22 patients all samples tested negative for COVID-19 in rRT-PCR. Discrepancies between rRT-PCR results of lab technician- and patient-collected swabs were observed in 12 nasopharyngeal and 13 oropharyngeal specimens. Positive lab technician-collected and negative patient-collected samples were observed in 10 and 5 nasopharyngeal and oropharyngeal specimens, respectively. Negative lab technician-collected and positive patient-collected samples were observed in two and seven nasopharyngeal and oropharyngeal specimens, respectively. The overall percentage of agreement among both nasopharyngeal and oropharyngeal swabs taken by a lab technician and patients was 76% with a kappa value of 0.49 (p =0.001). Conclusion: Based on our findings, lab technician-collected naso- and oropharyngeal swabs cannot be replaced by patient-collected ones with regard to COVID-19 rRT-PCR.
منابع مشابه
Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method
Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...
متن کاملinvestigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances
در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...
comparison of zoe and vitapex for canal treatment of necrotic primary teeth
چکیده ندارد.
15 صفحه اولEffectiveness of patient-collected swabs for influenza testing.
OBJECTIVE To compare the effectiveness of self-collected and health care worker (HCW)-collected nasal swabs for detection of influenza viruses and determine the patients' preference for type of collection. PATIENTS AND METHODS We enrolled adult patients presenting with influenzalike illness to the Emergency Department at Mayo Clinic, Rochester, Minnesota, from January 28, 2011, through April ...
متن کاملComparison between RT-PCR, NASBA and RT-LAMP Methods for Detection of Coxsackievirus B3
Viral myocarditis is a moderate disease, but it sometimes causes progressive cardiac disorder. Many different viruses have been considered as the agent of viral myocarditis, but Coxsackievirus of the B group, in particular of the Coxsackievirus B3 (CVB3), is more than fifty percent of cases of viral myocarditis. CVB3 is a positive single-stranded RNA virus and a member of the genus Enterovirus ...
متن کاملComparison of Nasopharyngeal and Oropharyngeal Swabs for the Diagnosis of Eight Respiratory Viruses by Real-Time Reverse Transcription-PCR Assays
BACKGROUND Many acute respiratory illness surveillance systems collect and test nasopharyngeal (NP) and/or oropharyngeal (OP) swab specimens, yet there are few studies assessing the relative measures of performance for NP versus OP specimens. METHODS We collected paired NP and OP swabs separately from pediatric and adult patients with influenza-like illness or severe acute respiratory illness...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره 4
صفحات 313- 319
تاریخ انتشار 2020-10-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023