چکیده مقاله:

Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic model prediction of Normal Tissue Complication Probability (NTCP). Materials and Methods: 25 left-sided breast cancer patients were selected. The planning target volume (PTV) and organs at risk (heart ad ipsilateral lung) were countered. The tangential technique of treatment planning consists of two optimized wedged beam (2FW) were compared to FIMRT plans for same patients. The FIMRT and 2FW was planned for delivery of 50Gy dose to the target for 25 fractions. The minimum dose, maximum dose, mean dose and homogeneity index (HI) of the dose for the PTV were obtained for both techniques.  Moreover, maximum and mean dose for the lung and heart tissues were obtained. The monitor unit (MUs) and the PTV97% were recorded. Paired samples t-test was used for statistical analysis and p<0.05 was considered as significant level. TCP and NTCP for radiation pneumonitis and late heart mortality was calculated with the Lyman model for organs at risk using dose-volume histogram (DVH). Results: the homogeneity index between the two techniques was significant (p>0.05), HI= 1.32 vs 1.10 for 2FW and FIF, respectively. Mean dose to the breast PTV as mean±standard deviation value was 46.6±0.5 Gy for FIMRT vs. 46.8±1.3 Gy for 2FW plans. The PTV97% was 92.5%± 3.2%, and 91.1%± 3.7 for the FIMRT and 2FW. The MUs of the 2FW plans and FIMRT plans were 326.4±11.2 and 212±10.3, respectively. With the FIMRT, the mean dose of the heart and the lung was (2.9Gy vs. 1.9Gy) and (12.1Gy vs. 8.3Gy) respectively; the maximum doses in the heart and lung were decreased significantly from (3.5Gy to 2.1Gy) and (15.8Gy to 10.2Gy) in favor of the FIMRT plans. TCP was 72.3% for FIMRT and 72.1% for 2FW plans. The NTCP for radiation pneumonitis was (0.4%±0.1%) and (0.6%±0.5%) for the FIMRT and 2FW techniques, respectively. The NTCP for late heart was (6.1%±2.1%) for the 2FW technique. However, it was reduced to (3.8%±1.9%) in the FIMRT technique. Differences of the NTCP values were statistically significant for both lung and heart (p<0.05). Conclusion: the treatment MUs were significantly reduced by the FIF-RT technique (p<0.05). For all organs, mean NTCP were lower for FIMRT than for the 2FW plans. The FIMRT delivered more homogenous dose to the target while maintaining or increasing the TCP. The FIMRT technique can be considered as a straightforward and fast technique to use clinically particularly in clinics that have not inverse IMRT.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: dosimetric and radiobiologic analysis

background: to analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (imrt) and 3 dimensional conformal radiotherapy (3dcrt) and selection of optimal photon energy for imrt treatments. material and methods: 24 patients with localized prostate carcinoma were planned for 3dcrt and imrt techniques. radiation dose of 54 gy with 2 gy/fraction, was planned to p...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  443- 443

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023