Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

نویسندگان

  • H.A. Nedaie
  • M. Aghili
  • M. Allahverdi
  • M. Esfehani
چکیده مقاله:

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prepared using 6 and 18 MV photon energies. The minimum dose (Dmin), maximum dose (Dmax) and mean dose (Dmean) to target (PTV) and organs at risk (OAR), Integral dose, Homogeneity Index and Conformity Index were compared for each plan. Also, Experimental measurements were performed using farmer ionization chamber on a patient based pelvic phantom. Results: On Average, six-field (6F1) plans, offer minimum dose to critical organs and sufficient dose to prostate. Increasing the beam energy lead to a decrease in Dmean of the bladder and femoral heads, as well as Dmax of PTV. The CI and ID were decreased by 4% and 11% respectively with increasing the energy and the number of beams. Experimental measurements were also in good agreement with calculations. 3D-CRT reduced Dmean of bladder, rectum and femoral heads and also CI and ID were significantly improved by 44.6% and 30.8%, respectively. Conclusion: Increasing the photon energy and number of beams, improve the treatment parameters of bladder, femoral heads and PTV, except the rectum. 3D-CRT offered the most conformity in the delivery doses to the prostate while sparing dose to OARs, uninvolved structures with lower integral dose. Iran. J. Radiat. Res., 2012 10(3‐4): 145‐150

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of conventional and 3d conformal treatments using linac energies for prostate cancer

background: to evaluate the dosimetric difference between conventional and three-dimensional conformal radiotherapy (3d-crt) using 6 and 18 mv x-ray photons. materials and methods: computed tomography scans of 26 pelvic patients were acquired and transferred to the 3d treatment planning system. for each patient, 8 conventional plans (3, 4, 5 and 6 fields) and one 3d-crt plan were prepared using...

متن کامل

The comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer

Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan an...

متن کامل

Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

متن کامل

the comparison of dose distribution of different 3d conformal and conventional radiotherapy plans for gastric cancer

aims: it was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. methods: this study was conducted on the ct simulation images of thirty patients diagnosed with gastric cancer. target volumes and the organs at risk were contoured. ap-pa reciprocal parallel field conventional plan an...

متن کامل

[Cost comparison of three treatments for localized prostate cancer in Spain: radical prostatectomy, prostate brachytherapy and external 3D conformal radiotherapy].

OBJECTIVE To compare the initial costs of the three most established treatments for clinically localized prostate cancer according to risk, age and comorbidity groups, from the healthcare provider's perspective. METHODS We carried out a cost comparison study in a sample of patients consecutively recruited between 2003 and 2005 from a functional unit for prostate cancer treatment in Catalonia ...

متن کامل

dosimetric comparison of various radiotherapeutic treatment plans using cobalt-60 and linac for prostate cancer

introduction: this study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (id), homogeneity index (hi) and conformity index (ci) in various treatment plans for prostate cancer. materials and methods: pelvic computed tomography (ct) scans of 27 patients were acquired and transferred to the rtdoseplan treatment planning system. for each patient, 8 co...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 10  شماره None

صفحات  145- 150

تاریخ انتشار 2012-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023