Comparison of apical transport in three rotary systems and one modified technique
نویسندگان
چکیده مقاله:
Comparison of apical transport in three rotary systems and one modified technique Dr. A.R. Farhad* - Dr. H. Bakhtiar*** - Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Endodontist. Background and Aim: Procedural errors such as canal transportation and loss of working length are mainly associated with stainless steel files with insufficient flexibility. Apical trans-portation may also be attributed to the cutting or non–cutting tip of rotary instruments. The aim of this investigation was to compare apical transportation in three types of rotary instruments (Hero642, Race and K3) using manufacturers' guidelines and a modified technique. Materials and Methods: Extracted maxillary or mandibular mesiobuccal roots of permanent human molars with a length of 19-23 mm and curvature between 20 – 40 degrees (according to the Schneider method) were studied. The initial patency of the experimental canals were at least ≠10 and maximum ≠15. The samples were divided into six groups of twenty canals. In the first three groups, canals were instrumented using rotary systems according to the manu-facturer's guidelines whereas in the 4th, 5th and 6th groups, prior to the instrumentation with rotary instruments, apical patency with ≠15 k hand file, ≠1-3 gates gliden, ≠2 peeso reamer and a full passive step back technique were used to create a better access to coronal and middle parts of the canal (modified technique). Statistical analysis was performed using Variance, Duncan and t – tests. Results: The mean degrees of apical transportation among groups instrumented according to the manufacturer's guidelines with Hero, Race and K3 rotary instruments were 2.79±1.12, 2.21±1.37 and 1.65±0.79, respectively and in samples instrumented with the modified tech-nique 2.64±1.54, 2.10±1.40 and 1.93±1.23 degrees of apical transportation were recorded in Hero, Race and K3 instruments, respectively. There was a statistically significant difference between the first three groups (P<0.05) that were instrumented according to the manufacturer's guidelines, but no statistically significant difference was found in apical transportation be-tween the modified technique groups and the manufacturer guideline groups (P>0.05) Conclusion: The use of modified technique, although leads to much easier instrumentation procedures, has no significant effect on the reduction of apical transportation degree as com-pared with the manufacturer's recommended method. Key words: Apical transportation – Rotary instruments – Modified technique
منابع مشابه
comparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولcomparison between conventional and alternative technique in extraction of maxillary molars
چکیده ندارد.
15 صفحه اولinvestigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances
در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...
MODIFIED ONE- FINGER LAPAROSCOPY TECHNIQUE
We used the modified one finger laparoscopy technique on 100 patients and found it to be successful in 87% of cases. No major complication occurred during or after such operations. However, we think that this technique is accompanied by three important problems: 1) The CO2 gas is lost f1"om the subumbilical incision, 2) A secondary fascial layer is present in some patients, and 3) There i...
متن کاملcomparison of apical extrusion of debris by using single-file, full-sequence rotary and reciprocating systems
objectives: during root canal preparation, apical extrusion of debris can cause inflammation, flare-ups, and delayed healing. therefore, instrumentation techniques that cause the least extrusion of debris are desirable. this study aimed to compare apical extrusion of debris by five single-file, full-sequence rotary and reciprocating systems. materials and methods: one hundred twenty human mandi...
متن کاملComparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars
Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 17 شماره 5
صفحات 30- 37
تاریخ انتشار 2005-08
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023