Comparison and evaluation of dosimetric and radiobiological parameters in two different treatment plans in stomach cancer by use of 3D CRT
نویسندگان
چکیده مقاله:
Introduction: In 3DCRT the number of therapeutic fields has dramatic impact on treatment results especially in stomach cancer. Traditionally, for radiotherapy of stomach cancer the therapeutic procedure was using two fields (AP- PA or AP Lateral with wedge) to achieve smooth and homogeneous dose distribution in tumor. But nowadays, adding lateral or oblique fields to aforementioned techniques lead to reducing dose to organ at risks (OARs) like spinal cord, liver, both kidneys and better dose distribution in tumor. Moreover, there are a several ways to evaluate traditional and novel techniques in 3DCRT for stomach cancer. for example, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) from radiobiological point of view and Homogeneity Index (HI), Conformity Index (CI) as a dosimetric parameters. Thus, the aim of this study is to assess and compare two different plans in stomach cancer by using homogeneity Index, conformity index, TCP and NTCP as guidance criteria in 3DCRT. Materials and Methods: In this study, 10 patients with stomach cancer were chosen. Two different of treatment plans; three fields (AP, PA, and lateral) and four fields (AP, PA and two laterals) were prepared. A photon beam of 6MV quality was used for both treatment plans in PCRT 3D as treatment planning system. Prescribed dose was 5o.4 Gy for tumor. Therapeutic aim for all treatment plans was to deliver at least 95% of prescribed dose to 97% of target volume while sparing organ at risks. The normalization of each plan followed the recommendation of ICRU report 50. The tumor volume selected for calculating the HI, CI and TCP and OARs for NTCP. Results:Average ratio of the calculated parameters in treatment plans of four fields over three fields with standard deviation (Mean /SD) was 1.05±0.13 for CI and 0.99±0.01 for HI. In addition, Treatment ratio for four fields over three fields was 1±0.02. Damage ratio to spinal cord and liver was 0.57±0.18 and 2.09±0.93 respectively for treatment plans with four fields in comparison of treatment plans by using of three therapeutic fields. Conclusion: Results show that, HI and CI parameters are approximately equal in two treatment plans. Therefore, both of the treatment plans are acceptable for clinical use. Assessment TCP and NTCP radiobiology parameter determined that, tumor control probability for both treatment plans are same but, damage probability of liver in three field treatment plan is less than over four fields while damage probability of spinal cord in four field treatment plan is lower than three fields treatment planning.
منابع مشابه
comparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولassessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks
testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...
Dosimetric comparison of treatment of left breast cancer using two different dose schedules Dosimetric comparison of treatment of left breast cancer using two different dose schedules
Background: To date, different kinds of treatment methods have been proposed for radiotherapy of cancer patients. Choosing the kind of treatment method affects the quality of the patient's treatment. This study aims to investigate the effect of the number of radiation treatment sessions on the dose received by the patient and the distribution of tumor dose and dose received by organs at risk in...
متن کاملinvestigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances
در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 34- 34
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023