Comparing the Microleakage of Bulk-Fill (flowable, packable) Composite Restorations and Conventional Light-cured Composites

نویسندگان: ثبت نشده
چکیده مقاله:

Introduction and aim: Bulk Fill composites have increased polymerization depth and their contraction stress, and cuspal deflection are reduced in comparison with conventional composites. Therefore, it is claimed that their microleakage is reduced. The aim of this study was to compare microleakage of (flowable and packable) Bulk Fill and conventional resin composites. Materials and Methods: This in vitro experimental study was done on sixty human extracted premolars. Standard class II cavities (4 mm in height, 3 mm in length bucco-lingually & 1.5 mm in axial depth) prepared in the teeth. The teeth were randomly divided into three groups based on the type of composite. Group I: Bulk Fill (Xtra Fill packable; Voco) composite, Group II: Bulk Fill flowable (Xtra base; Voco) and Group III: conventional composite (Grandio; Voco). Total-etch bonding system (5th generation) was applied in all cavities. After restoration, teeth were thermocycled. Finally, the microleakage rate was evaluated using a stereomicroscope. The data were analyzed using SPSS software, and Chi-square test. Results: The results indicated that there was no statistically significant difference between enamel and dentinal margins in Bulk Fill Packable and conventional composites (P=0.06). In Bulk-fill Flowable group, dentinal margins had greater dye penetration to enamel margin in the axial surface (P=0.02). There was no significant difference between the three groups in terms of marginal microleakage of enamel and dentin (P=0.4). Conclusion: Finally, we conclude that the use of Bulk Fill Flowable composites on dentinal cavity is not suitable with the manufacturer's recommended thickness. To prove these results, it is necessary to design and perform long-term laboratory and clinical studies. Furthermore, the use of the incremental technique for placement of composites -even with the Bulk-filled group- sounds to be more logical.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Shear Bond Strength of Bulk-Fill Composites, Packable and Flowable, as Well as Conventional Light-Curing Composite

Introduction: This study aimed to compare the Shear Bond Strength (SBS) of two bulk-fill composites versus a conventional resin composite. Materials and Methods: In this study, 60 sound extracted human premolars were selected and sectioned horizontally from one-third of the coronal crown to expose dentin using a low-speed cutting saw. The dentin bonding agent was applied to all specimens, then...

متن کامل

Microleakage of Flowable Composite Restorations

Author’s response I totally agree with comments by Pitak-Arnnop et al which emphasizes the importance of clinical relevance (though not statistically significant) and 95% CI confidence interval in today's publication process this change of mindset had evolved over many years of education on research & biostatistics. I must clarify that the present article is highlighting the well-known bias of ...

متن کامل

In-Vitro Evaluation of Microleakage of Class II Cavities Restored with Bulk-Fill Flowable Composite

Background and Aim: Composite placement poses many challenges, especially in the gingival floor with dentinal margins. Microleakage is one of the factors affecting the longevity of dental restorations. We aimed to compare the microleakage of cavities filled with bulk-fill composite at enamel and dentinal margins. Materials and Methods: In this experimental study, a total of 102 sound human pre...

متن کامل

Microleakage of Bulk-Fill Composites at Two Different Time Points

Objectives: Microleakage is the main concern in composite restorations. This study aimed to compare the microleakage of two bulk-fill and one conventional composite at two different time points. Methods: Class II cavities were prepared in 60 premolar teeth and divided into six groups of 20. Groups 1 and 4 were incrementally filled with Grandio composite. Groups 2 and 5 were filled with X-tra...

متن کامل

Microleakage of Two Bulk Fill and One Conventional Composite in Class II Restorations of Primary Posterior Teeth

Objectives This study aimed to assess and compare the microleakage of two bulk fill and one conventional composite in class II restorations of primary posterior teeth. Materials and Methods This in vitro, experimental study was conducted on 60 primary mandibular second molars, which were randomly divided into three groups. Standard class II cavities were prepared in teeth and restored with 3M...

متن کامل

Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites.

OBJECTIVE The aim of this study is to evaluate if the cytotoxic effects of the Surefil SDR flow, bulk fill flowable composite resin and three conventional flowable materials (Venus Diamond Flow, Filtex Supreme XTE Flowable and Enamel plus HRi Flow) correlated with the conversion degree (DC); hardness and depth of cure are also assessed. MATERIALS AND METHODS Disks of each materials--cured usi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 4

صفحات  7- 7

تاریخ انتشار 2018-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023