Compare the organs at risk in breast-conserving three- dimensional conformal radiotherapy (3D-CRT) based on patient's breast size

نویسندگان

  • Mehran Yarahmadi Medical Physics Dept., Kurdistan University of Medical Sciences, Sanandaj, Iran.
  • S Yazdani MSc of Medical Physics, Department of Medial physics, Kermanshah University of Medical Sciences, Kermanshah, Iran
چکیده مقاله:

Introduction: Breast cancer is the most common cancer among women. Radiotherapy plays an important role in the treatment of breast cancer and essential part of the standard treatment after breast-conserving surgery, routinely done to eliminate the microscopic residual cancer. The heart and lungs are one of the most important organs at risk of breast cancer radiotherapy that their exposure are unavoidable. Pneumonia and Pericardia are the most common complications of lung and heart radiation exposure, respectively. Materials and Methods: In this study, 20 patients undergoing radiotherapy after breast-conserving surgery were studied. The mean age of patients was 45 years old in the range of 30-60 years. Patients were treated by 3D-CRT with a single-isocenter tri-field technique including two apposite tangent fields and a supraclave field. To optimize the dose distribution, the wedge with suitable angle was placed in front of the beam for each field. The heart and right and left lung in each slice were contoured based on RTOG by oncologist and physicist, and was reconstructed in three dimensions by treatment planning system (Isogry version 4.1). Dose-volume histogram (DVH) for organs at risk were calculated and extracted. Parameters V5, V10, V20, V30, V40 and also Dmax and Dmean for organs at risk were extracted. Patients were classified into two groups, large and small breasts; then statistical analysis was performed with the SPSS software. Results: At all levels of the dose for the large breast group, a greater percentage of the heart was involved, but there was no significant statistical difference between the small breast group (p>0.05). In lungs, at all levels examined, the received dose of large breast group was higher than those of the small breasts, but this difference was not statistically significant (p>0.05). Only the Dmax parameter between the two groups was significant (p=0.01). Conclusion: The received dose of organs at risk, better results were obtained in a small breast; but no threshold of exposure risks. Therefore, paying attention to this group of patients is more clinically important. It is recommended that treatment planning for patients with large breast size more carefully done.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compare the organs at risk in breast-conserving three- dimensional conformal radiotherapy (3D-CRT) based on patient\'s breast size

Introduction: Breast cancer is the most common cancer among women. Radiotherapy plays an important role in the treatment of breast cancer and essential part of the standard treatment after breast-conserving surgery, routinely done to eliminate the microscopic residual cancer. The heart and lungs are one of the most important organs at risk of breast cancer radiotherapy that th...

متن کامل

Factors of influence on acute skin toxicity of breast cancer patients treated with standard three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery (BCS)

PURPOSE/OBJECTIVES Standard 3D-CRT after BCS may cause skin toxicity with a wide range of intensity including acute effects like erythema or late effects. In order to reduce these side effects it is mandatory to identify potential factors of influence in breast cancer patients undergoing standard three-dimensional conformal radiation therapy (3D-CRT) of the breast and modern systemic therapy. ...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT

BACKGROUND.: Treatment planning for head and neck (H&N) cancer is complex due to the number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant OAR must also be taken into consideration. Intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) are both common H&N treatment techniques with very different planning approaches. Alth...

متن کامل

Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

INTRODUCTION Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  157- 157

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023