Change of Hemoglobin Concentration with nano particles can predict breast cancer using near infrared source?

نویسندگان

  • Bahman Alipour Medical radiation sciences research group, Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Parinaz Mehnati Medical radiation sciences research group, Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Roya Salehi Medical radiation sciences research group, Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
چکیده مقاله:

Introduction: Early detection and treatment of breast cancer may be helping to save the lives of patients. Many new techniques have been urban to detect breast cancer. One of them is the use of nano-particles for accuracy and early diagnosis after photo transfer. In this study, rod gold nano particles was used according their ability to change light source transfer intensity.   Material and methods: rod gold nano particles and bloods with 1, 2 and 4 hemoglobin concentrations used to simulate breast cancerous conditions. Nanoparticles with each concentrations of hemoglobin injected into the breast phantom including vessels and transmitted light intensity measured by power meter. Light source was near infrared at 635 wavelengths.   Results: The intensity of the passing lights from normal hemoglobin concentrations was 6.71μw but when measured in the cancerous breast, it declined to 5.59μw and 3.97μw, for twice and four times the concentration of Hb in without nanoparticle condition, respectively. . When the nanoparticles were blended with hemoglobin concentrations The intensity of the passing lights were determined to be 3.42μw, 2.13μw, and 1.98μw, for, normal, twice and four times the concentration of Hb, respectively.   Conclusions: This study showed that addition of rod gold nano particles to different concentration of hemoglobin provides an effective variation on the near infra red transferring intensity. This study suggests that near-infrared light accompanied by gold nanoparticles has the potential for early breast cancer diagnosis

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

synthesis of amido alkylnaphthols using nano-magnetic particles and surfactants

we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.

15 صفحه اول

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Near-infrared imaging of the human breast: complementing hemoglobin concentration maps with oxygenation images.

We have previously reported a comparison between edge-corrected near-infrared optical mammograms and those that have undergone a further image-processing step based on a spatial second derivative. In this work, we go a step further by combining the second-derivative images from four wavelengths (690, 750, 788, and 856 nm) to obtain oxygenation-index images. While the spatial second derivative i...

متن کامل

assessing absorption coefficient of hemoglobin in the breast phantom using near-infrared spectroscopy

objectives in this study, the absorption coefficient of hemoglobin (hb) was used to distinguish between normal and abnormal breast tissue. materials and methods a near-infrared source (637 nm) was transmitted from major and minor vessels of a breast phantom containing 2×, 4× concentrations of oxy- and deoxy-hb. the absorption coefficients were determined from spectrometer (sm) and powermeter (p...

متن کامل

Prediction of Plasma Hemoglobin Concentration by Near-Infrared Spectroscopy

The estimation of plasma hemoglobin concentration (Hb) is among one of the daily activities in the practice of clinical anesthesiology. The near-infrared spectroscopy of the brain (rSO(2)) represents a balance between cerebral oxygen delivery and consumption. This study was designed to assess the value of rSO(2) in the prediction of the Hb level while other variables were mathematically control...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  422- 422

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023