Calculation of air gaps between bolus and skin on the dose received from the skin

نویسندگان

  • Ahmad Mostaar Medical Physics and Biomedical Engineering Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Ghazaleh Sadrieh Khajoo Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Mahdi Salehi Barough Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Mohammad Ali Ostadrahimi Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
چکیده مقاله:

    Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. For close - to - surface tumors, the surface of the skin can be used to increase the surface dose so that all or part of the bunch area can fall into bolus, thereby increasing the dose of the skin. The air gaps between bolus and skin can affect the dose of skin, especially if the skin is only the target of treatment. For this purpose, the effect of energy, bolus thickness, the amount of air gap, field dimensions and angle of field contact angle will be evaluated. Materials and Methods: In this study, the MCNPX calculation code is used to simulate the linear accelerator of Siemens to determine the effects of air gaps between bolus and skin. The studied fields were chosen in this study with dimensions 4×4 and 10×10 cm2. it also simulated a water phantom at SSD=100 cm and bolus thickness 0.5,1 cm in distances 0, 0.5 cm. Results: For field sizes 4×4 cm2 with 6 photon beam The bolus was as thick as 0.5 cm in the distance of 0 and 0.5 cm from the phantom level with a percent of surface dose to the maximum dose in the absence of the air gaps with %104.615 in the presence of air gaps %101.866 and the bolus thickness of 1cm in a same distance from the phantom level with a percent of surface dose to the maximum dose in the absence of the air gaps with %106.89 in the presence of air gaps %100.47. Also for field sizes 10×10 cm2, thickness of 0.5 cm in distance of 0 and 0.5 cm, from the phantom level with a percent of surface dose to the maximum dose in the absence of the air gaps with %99.62 in the presence of air gaps %97.74. Conclusion: For field size 10×10 cm2 Dsurf is largely unaffected by air gaps. However, smaller air gap results in shallower dmax for 6 MV photon beams at all fields sizes. Special consideration should be taken to reduce air gaps between bolus and skin for field sizes smaller than 10×10 cm2 or when surface contour variations are greater or when the bolus covers small area and at the border of the field.          

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

on translation of phatic communion and socio-cultural relationships between the characters of the novels

phatic communion is a cultural concept which differs across cultures. according to hofstede (2001), the u.s. tends to have individualistic culture; however, asian countries tend to have collectivistic cultures. these cultures view phatic communion differently. in individualistic cultures like u.s., phatic communion reflects speakers’ socio-cultural relationships in conversations. to see whether...

15 صفحه اول

on the relationship between the knowledge of collocations and writing proficiency

بررسی رابطه دانش همنشینی لغات و مهارت نوشتاری در زبان انگلیسی چکیده این پژوهش درصدد آن است تا سه مسئله زیر را مورد بررسی قرار دهد: الف) وجود یا عدم وجود رابطه بین دانش زبان آموزان در حوزه همنشینی لغات با یکدیگر و دانش آنها در مهارت نوشتاری زبان انگلیسی؛ ب) یافتن پاسخی به این سوال که آیا تمامی انواع همنشینی های لغوی زبان انگلیسی به یک میزان برای زبان آموزان دشوارند یا خیر؛ پ) مقایسه زبان آمو...

15 صفحه اول

on the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors

the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...

15 صفحه اول

Influence of an Air Gap between Bolus and Patient Skin on Electron Beam Dose Characteristics

Introduction In electron beam therapy bolus is often used to conform as closely as possible to the target volume while avoiding critical structures in the depth. In most cases a flexible bolus can cover the skin without air gap. However, under certain conditions it is difficult –or even not possible– to avoid air gaps between bolus and patient without reducing treatment quality. In a special cl...

متن کامل

the effect of traffic density on the accident externality from driving the case study of tehran

در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  276- 276

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023