Calculation and Comparison of Heart Integral Dose in The Treatment of Esophagus Cancer with Three Photon Energies & Using CT Simulation and Treatment Planning System

نویسندگان

  • A. Kazemian Assistant Professor, Cancer Reserch Center, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • H. Gharaati Associate Professor, Cancer Reserch Center, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
  • H. Nedaie Ph.D. Student in Medical Physics Dept., Cancer Reserch Center, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • K. Zahedi M.Sc. in Nuclear Engineering, Azad University Tehran, Iran
چکیده مقاله:

Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a  high  incidence  rate  among  other  countries.  Radiotherapy  is  one  of  the  three  methods  (surgery,  radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method  of treatment, the organs such as heart and spinal cord are regarded as organs at risk (OAR) which their  dose should be kept below the tolerance level.  Different techniques have been used in conventional radiotherapy, among which two parallel opposed  fields (POP) is used more often either for the whole course of the treatment or 2/3 of the fractions. In  this technique, a great portion of the spinal cord may be involved in the treatment volume.  The rate of treatment success may depend on the tolerance dose of heart and cord which act as the  limiting factor.  Materials and  Methods:  In this  study, 10 patients  with S.C.C.  of  esophagus having  indication  for  external radiotherapy were selected. The CT scan simulations were performed for all the cases and  their data were digitized to be used in computerized treatment planning system. Treatment planning for  three photon beam energies (Co-60, 6 and 10 MV) are obtained for each individual patient under the  same geometry and dose. The integral dose, absorbed dose and dose volume histogram (DVH) of the  heart and target were calculated for all the cases.  Results: The maximum point dose in the heart is 140, 125 and 115% of the reference point for Co-60,  6 and 10 MV, respectively. The integral dose for the largest A-P patient was found to be 55.33, 54.17  and 51.66 Gy.Kg for Co-60, 6 and 10 MV, respectively. In using 10 MV beam, 7% reduction in the  integral dose of the heart was obtained. Alternatively, by using 6 MV beam, a reduction of only 2%  was observed. The integral dose of the heart for the 10 MV beam had a 5% reduction in comparison to  6 MV beam.   Discussion and Conclusion:  Since lower energy beams cause a higher integral dose to the heart and  cord, the use of higher energy photon beams in the case of deep seated tumors and large size patients  are unavoidable. In spite of the advantages of cobalt machines, its energy is not suitable for deeply  suited tumors. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

calculation and comparison of heart integral dose in the treatment of esophagus cancer with three photon energies & using ct simulation and treatment planning system

introduction: esophageal cancer is one of the most frequently occurring cancers in iran and having a  high  incidence  rate  among  other  countries.  radiotherapy  is  one  of  the  three  methods  (surgery,  radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. in this method  of treatment, the organs such as heart and spinal cord are regarded as organs at r...

متن کامل

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

متن کامل

the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region

چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...

15 صفحه اول

The effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers

Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis.   Materials and Methods: Seven patients with pelvis area ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 2

صفحات  77- 84

تاریخ انتشار 2005-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023