Calculating Contra-Lateral Breast’s Absorption Dose in Different Radiotherapy Methods of Large Breasts Cancer

نویسندگان

  • Mehdi Salehi Barough Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Mohammad Rahgoshay Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Sahar Beyranvand Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
چکیده مقاله:

Introduction: Breast cancer is one of the most common known cancers in women all around the world. It is the most common cause of death in women after lung cancer. Radiotherapy is a method for therapy of cancer in which certain dose of high energy radiations is used to destruct cancer cells. Radiotherapy is designed so that radiation of eartain does to the target area in body is allowed. In this therapy more radiation dose should be used in tumor and the least dose is used in normal tissues. In this design, Contra-lateral breast’s absorption dose in different radiotherapy methods in large breasts is calculated. In large breasts, normal tissues and more sensitive organs exist in the field due to its anatomical structure. Materials and Methods: Measurement is performed by 3D Aculips therapy design system and EBT3 Gap chromic film and TLD. This plan was an experimental study. 60 time radiations were used by X-Varian linear medical accelerator device with 6MV energy that 30 times were performed by Gap chromic film and 30 times were performed by TLD. All radiations were performed on the phantom due to protective problems. In this work, CT-simulator phantom was used and then, it was transferred into therapy design computer. TLD and Gap chromic film were installed on Contra-lateral breast, and in all radiation steps, 100 manitor unit (Mu) were used. Results: After calibrating TLD, first, absorbtion does in breast CT scan is calculated by TLD. This dose is 1.6 cGy. We are inevitable to remove this dose. In radiotherapy planing, three methods are studied. In the first method, common two tangents method, results indicate that a part of the contra-lateral breast tissue and internal memolary lymph nodes are in the radiation field, therefore a part of the breast is placed because the breasts are large. In this method, dose maximum is 84.1 cGy. In the second method two photon-radiation field are placed in the medial area and a part of breast is removed and dose used for the breast is 15cGy. In the method of combination of photon and electron, a part of the main breast is removed from the radiation field. The removed area is in internal area, which is covered by electron tangent with internal field. In this method, the maximum dose reachs to 6 cGy. After calculating by radiotherapy planing, we perform exprimental calculation by TLD in certain points. In usual therapy method, a part of the contra-lateral breast is in radiation field, and it receives a full dose. In edge of field-therapy, absorpthion dose is 83.2% of perspective dose. In this method, tivo beside photon fields reach to 14.9% of perspective dose; and two electron and photon fields reach to 6% in another method for calculating absorpthion dose, after calibration of Gap chromic film of absorption dose, three used methods are calculated, and by putting film on contra-lateral breast, dose phantom is evaluated. From performed measurement, dose level in usual method, two photon fields were 84.1% of perspective dose. In method of two photon fields together percentage of the perspective dose was 15.1%, and for photon-electron fields this value was 6.4%. Conclusion: With respect to this design, it can be concluded that if two beside photon- electron fields method is used, dose entered into the contra-lateral breast will be significantly reduced. However, in this design, dose for other sensitive organs must be considered

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system

Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...

متن کامل

Segmentation of the Breasts in MR-Mammography

Introduction Contrast enhanced MR mammography is a highly sensitive method in breast cancer detection. Tracking the inflow and washout of contrast agents is used to classify suspect tissue as malign or benign. Segmenting the breasts is needed in order to: • quantify the tissue in fat and parenchyma, • make local elastic motion correction [1] faster and more robust by restricting the registratio...

متن کامل

Women with large breasts are at an increased risk of advanced breast cancer

BACKGROUND The risk of nodal metastasis is higher in women with bigger breast. It is not clear if this increase is due to the size of the breast (largely related to obesity) or is the result of larger tumour size at presentation (due to delayed diagnosis). It is hypothesised that women with large breasts are more likely to have node positive disease mainly attributable to their breast size. P...

متن کامل

Bilateral giant juvenile fibroadenoma of breasts

An 11-year-old girl with rapidly enlarging bilateral breast lumps is reported. It was diagnosed as a case of juvenile fibroadenoma following fine needle aspiration cytology and confirmed on histopathological examination of the excised specimens.

متن کامل

Case Study 1 : Mammary Dysplasia ( Fibrocystic Breasts )

History: Colleen, a 34 year old white female, presented for treatment of severe breast pain, known as mastalgia, of five years duration. The pain was cyclical (menstrually related), however, she had some tenderness throughout the entire month. Colleen described multiple lumps in each breast, and about two years prior had a large lump drained. It was at that time that her gynecologist termed her...

متن کامل

A comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  9- 9

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023