Cadmium contamination of drinking water and its treatment using biological chelators

نویسندگان

  • A Amiri Dept. of Chemistry, Payame Noor University, P.O. Box, 19395-3697, Tehran, Iran.
  • Z Mirhoseiny Dept. of Chemistry, Payame Noor University, P.O. Box, 19395-3697, Tehran, Iran
چکیده مقاله:

Background: Cadmium (Cd) is an extremely toxic metal and environmental exposure to Cd has been particularly problematic in the world. Oral exposure to Cd may result in adverse effects on a number of tissues, the immune system, and the cardiovascular system. Compounds containing Cd are also carcinogenic. The presence of Cd in drinking water resources in the southeastern region of Rafsanjan plain (Iran) at concentrations greater than acceptable limits may result in various adverse health effects. The aim of this research was to test the chelation potency of deferasirox (DFS or ICL670), a tridentate metal chelator, and deferiprone (L1), a bidentate metal chelator, in the mobilization of Cd in Cd-exposed rats as a biological model. Materials and Methods: Male Wistar rats were exposed to 40 mg/kg body weight of cadmium chloride in drinking water for 6 weeks, followed by treatment with DFS (100 mg/kg body weight, oral, once daily) and L1 (100 mg/kg body weight, oral, once daily), alone or in combination, for 7 consecutive days. After chelation therapy, the rats were anesthetized by ether vapor and immobilized by cervical dislocation. Then, their heart, liver, kidneys, intestine, and blood were sampled for clinical hematological variables and determination of Cd and Fe concentration by inductively coupled plasma optical emission spectrometry (ICP-OES). The data were subjected to statistical analysis using Student’s t-test. All Ρ values of less than 0.05 were considered significant. Results: The results show that both chelators (DFS and L1) increase the removal of Cd from the tissues. No effects of Cd or any of the two treatments (L1 or DFS) were observed on white blood cell (WBC) count, red blood cell (RBC) count, and hemoglobin‎ (Hb) level. Conclusions: The comparison of single and combined therapy showed that the combined chelation therapy (DFS + L1) was more effective in depleting Cd concentration in soft tissues.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

cadmium contamination of drinking water and its treatment using biological chelators

background: cadmium (cd) is an extremely toxic metal and environmental exposure to cd has been particularly problematic in the world. oral exposure to cd may result in adverse effects on a number of tissues, the immune system, and the cardiovascular system. compounds containing cd are also carcinogenic. the presence of cd in drinking water resources in the southeastern region of rafsanjan plain...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

Microbial characterization of biological filters used for drinking water treatment.

The impact of preozonation and filter contact time (depth) on microbial communities was examined in drinking water biofilters treating Ohio River water which had undergone conventional treatment (coagulation, flocculation, sedimentation) or solutions of natural organic matter isolated from groundwater (both ozonated and nonozonated). With respect to filter depth, compared to filters treating no...

متن کامل

Water contamination events in UK drinking-water supply systems.

Water supply companies in the UK have a duty under prime UK legislation to notify the Drinking Water Inspectorate of events affecting or potentially affecting the quality of drinking-water supplies. Under the same legislation, the Inspectorate has a duty to investigate each event. After assessing all of the information available, including companies' reports, the Inspectorate advises on the way...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 4

صفحات  223- 228

تاریخ انتشار 2015-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023