Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)

نویسندگان

  • Alireza Kamali asl Department of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran
  • Faezeh Vedaei Department of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran and Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Faraz Kalantari Research Institute for Nuclear medicine, Tehran University of Medical Sciences, Tehran, Iran and Department of Medical Physics, Tarbiat Modares University, Tehran, Iran
  • Mohammad Reza Ay Research Center for Science and Technology in Medicine; Research Institute for Nuclear medicine; Departments of Medical Physics and Biomedical Engineering, , School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Mojtaba Ansari Department of Nuclear Medicine, Imam Hosein Hospital, Shahid Beheshti Universuty of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis with SPM. Methods: The study population consisted of twenty normal subjects (11 male, 9 female, and age 30-40 years). SPECT images were reconstructed using filter back projection and attenuation correction was done by the Chang method. The SPECT imagings was obtained 20 min after intravenous injection of 740-1110 MBq (20-30 mCi) of Tc99m-ECD and were acquired on 128×128 matrices with a 20% symmetric energy window at 140 keV. These data publicly distributed by the Society of Nuclear Medicine of Toronto Hospital. The data was standardized with respect to the Montreal Neurological Institute (MNI) atlas with a 12 parameter affine transformations. Images were then smoothed by a Gaussian filter of 10 mm FWHM. Significance differences between SPECT images were estimated at every voxel using statistical t-test and p-value as the significant criteria was set at 0.05. Results: The contrast comparing non attenuation corrected to attenuation corrected images suggest that regional brain perfusion activity increase in the cerebrum, frontal (T-value 12.06) , temporal (T-value 10.63) and occipital (T-value 9.31) lobe and decrease in the sub-lobar, extra-nuclear (T-value 17.46) and limbic lobe, posterior cingulate (T-value 17.46) before attenuation correction compare with attenuation correction. Conclusion: It can be concluded that applying attenuation correction in brain SPECT can effectively improve the accuracy of the detection of activation area (p<0.05).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

assessment of the impact of applying attenuation correction on the accuracy of activity recovery in tc99m-ecd brain spect of healthy subject using statistical parametric mapping (spm)

introduction: photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed single photon emission computed tomography (spect) images. the aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...

متن کامل

assessment of the efficiency of s.p.g.c refineries using network dea

data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...

the effects of error correction methods on pronunciation accuracy

هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...

15 صفحه اول

the impact of training on second language writing assessment: a case of raters’ biasedness

چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...

15 صفحه اول

the impact of using inspirational quotes on abstract vocabulary recall

the present study is an attempt to investigate the potential impact of inspirational quotes on improving english abstract vocabulary recall. to achieve this goal, a multiple choice language proficiency test of 60 items including vocabulary and grammar component was administered to a sample of 63 second-semester male and female students whose age ranged between 17 to 22 and they were studying en...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 19  شماره 2

صفحات  52- 59

تاریخ انتشار 2011-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023