Assessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches

نویسندگان

  • C. Kian Yern School of Civil Engineering, Universiti Sains Malaysia, Penang, Malaysia
  • E. Noroozinejad Farsangi Department of Earthquake Engineering, Faculty of Civil and Surveying Engineering, Graduate University of Advanced Technology, Kerman, Iran
  • F. Mohamed Nazri School of Civil Engineering, Universiti Sains Malaysia, Penang, Malaysia
  • M. Moffed Kassem School of Civil Engineering, Universiti Sains Malaysia, Penang, Malaysia
چکیده مقاله:

Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models using POA in EC8 is assessed. Later on, empirical accuracy of fragility curves generated by POA (using SPO2FRAG software) is studied and verified through Incremental Dynamic Analysis (IDA) results.  Four models of regular and soft storey frame of 5- and 11-storey varying heights were designed according to Eurocode 2 (EC2) and (EC8). The simulation is performed in a NL platform to carry out POA and IDA. Capacity curve obtained is served as main input in SPO2FRAG software to generate fragility curve. Then, IDA is performed to generate IDA and fragility curves. Peak ground acceleration, PGA was converted into corresponding Sa(T1) using design spectrum from EC8. Performance levels of Life Safety (LS) and Near Collapse (NC) proposed by Vision-2000 have been the main interest in this study. Results shown that the base shear calculated by using Lateral Force Method in EC8 is adequate. Fragility curve generated by SPO2FRAG, has good comformity with IDA-based fragility estimation for regular 5-storey model; however, some deviation is observed for soft storey model (5-storey). All 11-storey frames shown unsatisfactory match of fragility curves from what was generated by SPO2FRAG, compared to IDA results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

diagnostic and developmental potentials of dynamic assessment for writing skill

این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...

15 صفحه اول

Fragility Curves of Existing RC Buildings Based on Specific Structural Performance Levels

In seismic risk mitigation policies, fragility functions of existing buildings play a fundamental role. In this paper, a procedure to develop analytical fragility curves for Moment Resisting Frame Reinforced Concrete buildings is presented. The design of the selected building typologies was performed according to the codes at the time of construction using force-based methods and the state of t...

متن کامل

Study on corollary of seismic base isolation system on buildings with soft storey

Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious struc...

متن کامل

Fragility Curves for Reinforced Concrete Frames with Lap-Spliced Columns

Placing column lap-splice in the locations of possible nonlinear deformation may adversely affect the structures response to strong ground motions. Localization of damage in splice zone may change the structural response and prevent the load redistribution and development of a uniform pattern of nonlinear excursions among the various members. Validated by existing laboratory experiments, this s...

متن کامل

Fragility Curves Derivation for a Pile-Supported Wharf

This study aims to develop seismic fragility curves for a typical pile-supported wharf. Fragility curve is one of the popular tools in seismic performance evaluation of a structure. The software FLAC2D was used to simulate the seismic performance of the wharf structure. Using eight time history records, occurred in past, as seismic loading, incremental dynamic analysis (IDA) was applied for sei...

متن کامل

FRAGILITY CURVES FOR STRUCTURES EQUIPPED WITH OPTIMAL SATMDs

In this paper, a procedure has been presented to develop fragility curves of structures equipped with optimal variable damping or stiffness semi-active tuned mass dampers (SATMDs). To determine proper variable damping or stiffness of semi-active devices in each time step, instantaneous optimal control algorithm with clipped control concept has been used. Optimal SATMDs have been designed based ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 31  شماره 12

صفحات  2016- 2021

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023