Assessment of compliance to radiation safety and protection at the radiology department
نویسندگان
چکیده مقاله:
Background: Several potential challenges with radiation protection (RP) and safety culture in radiology departments need to be addressed. This study assesses radiographers’ adherence to radiation protection practices in radiology departments. Materials and Methods: A cross-sectional study was conducted among radiographers; 210 self-administrated questionnaires were sent to the participants. An analysis was conducted to determine participants’ adherence to radiation protection practices, including the implementation of personal protection, patient and environmental protection. The educational level of the radiographers, their years of experience and sociodemographic characteristics were assessed and compared. Results: The percentage of radiographers’ adherence to practices related to environmental protection, patient protection and self-protection were 75.1%, 60.4% and 45.7%, respectively. The overall adherence to radiation protection practices score was 75.2%±18.5, where 57.4% of the radiographers exhibited good adherence, 26.9% exhibited moderate adherence and 15.7% had poor adherence. The adherence score was significantly higher among elder radiographers (P<0.0001) and more experienced ones (P=0.001). However, no significant difference in adherence score was found in relation to the radiographers’ educational qualifications. Conclusion: Forty percent of the radiographers’ practices proved relatively unsatisfactory in implementing radiation protection. Thus, proactive steps and corrective actions are necessary to improve radiographers’ knowledge of international standards of proper radiation protection practices.
منابع مشابه
A Survey on the Radiation Protection Status among Radiology Staff
Introduction: Radiation exposure during radiological examination is a health concern, of which radiology professionals should be cognizant. We sought to evaluate the radiation protection knowledge, attitudes, and practice (KAP) amongst radiology staff of hospitals across 10 provinces of Iran. Materials and Methods: For evaluating the level of radiation protection KAP, 553 radiology staff were e...
متن کاملRadiation Protection in Diagnostic Radiology
This paper summarizes technological advances in diagnostic radiography, fluoroscopy and computed tomography, mainly the developments in digital detectors and helical CT scanners with multiple-row detectors. It reviews dosimetric concepts and presents the most up-to-date information on the global patterns of use of radiological modalities as well as the trends in diagnostic medical exposure dose...
متن کاملLess radiation in a radiology department than at home
OBJECTIVE To compare the total work-related radiation dose in our department of radiology with the dose in Dutch residences, taking x-ray radiation, external natural radiation and radon into account. METHODS Annual doses due to exposure to x-rays and external natural radiation were derived from the measured personal dose equivalent [H(p)(10)] of 144 workers. Additionally, departmental (222)Rn...
متن کاملRadiation Protection in Interventional Radiology
Interventional procedures are used by a significant number of medical specialities. Radiation protection (RP) for patients and staff is one of the main issues in Interventional Radiology (IR). UNSCEAR, ICRP and IAEA have devoted significant time over the last years to improve radiation safety in IR. Several combined factors: prolonged localized fluoroscopy, multiple radiographic exposures, and ...
متن کاملRadiation Safety Assessment of the New Neutron Radiography System at Tehran Research Reactor
Recently, a new Neutron Radiography (NR) beam line has been designed, constricted, installed and tested based on the use of E-beam tube of Tehran Research Reactor (TRR). Initial tests have been shown that the system can be used for different samples and purposes such as nuclear plates and rods fuels. For this end the system need a suitable irradiation room which should be installed at the NR b...
متن کاملthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 17 شماره 3
صفحات 439- 446
تاریخ انتشار 2019-06
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023