Assessment of compliance levels of effective doses in pediatric CT
نویسندگان
چکیده مقاله:
Introduction: Computed tomography (CT) is a medical imaging modality that produces 3-D cross-sectional images of tissues using several X-ray projections at different angles. Since its introduction in the 1970s, CT usage has been on the increase for both adults and pediatrics. A major challenge of this modality is the high doses of radiation exposure to patients, especially in pediatrics, who are more radiosensitive compared to adults. Hence, the need to ensure that radiation safety standards are adhered to. This will go a long way in reducing the adverse effects of radiation. The aim of this study was to assess the level of compliance to international dose reference levels (DRLs) in terms of effective doses in pediatric CT scans conducted in three Iraqi hospitals. Materials and Methods: CT brain and abdomen/pelvis examinations were conducted for pediatric patients aged between few months and 15 years in three Iraqi hospitals (Al Wasiti, Neuroscience and Al Omara). All scans were performed on a Somatom Sensation® 16 multidetector CT (MDCT) scanner with a Straton® X-ray tube (Siemens, Erlangen, Germany) utilising automatic tube current modulation (CARE Dose4DTM; Siemens, Erlangen, Germany). Volumetric CT dose index (CTDIvol) and dose length product (DLP) were collected for 180 patients (60 in each hospital). Afterwards, their effective doses were estimated from DLP values and compared with international DRLs. Results: Brain CT: The DLP values obtained for Al Wasiti, Neuroscience and Al Omara hospitals were in the range; 789-918.8 mGy.cm, 833-874.6 mGy.cm and 627.6-810 mGy.cm respectively, while their corresponding effective doses were in the range; 1.8-2.09 mSv, 1.9- 2.06 mSv and 1.43-1.83 mSv. Abdomen/Pelvis: The DLP values obtained for Al Wasiti, Neuroscience and Al Omara hospitals were in the range; 392.9-425.8 mGy.cm, 355-395 mGy.cm and 314.8-383.6 mGy.cm respectively, while their corresponding effective doses were in the range; 6.65-7.22 mSv, 6- 6.7 mSv and 5.34-6.51 mSv. Using the International Commission on Radiological Protection (ICRP) publication 103 as basis for assessing compliance level, for brain CT we observe slightly higher values in Al Wasiti and Neuroscience hospitals while Al Omara was similar to the international DRLs. However, for abdomen/pelvis CT examinations, the effective doses in all three hospitals were within the acceptable limits of international DRLs. Conclusion: This study has shown an encouraging level of compliance towards adequate radiation protection management in pediatric CT examinations among the three hospitals. Although, the best compliance level was observed in Al Omara hospital. Regular monitoring should be enforced to ensure that CT doses delivered to pediatric patients are as low as reasonably achievable without compromising diagnostic quality.
منابع مشابه
the role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
assessment of the park- ang damage index for performance levels of rc moment resisting frames
چکیده هدف اصلی از طراحی لرزه ای تامین ایمنی جانی در هنگام وقوع زلزله و تعمیر پذیر بودن سازه خسارت دیده، پس از وقوع زلزله است. تجربه زلزله های اخیر نشان داده است که ساختمان های طراحی شده با آیین نامه های مبتنی بر نیرو از نظر محدود نمودن خسارت وارده بر سازه دقت لازم را ندارند. این امر سبب پیدایش نسل جدید آیین نامه های مبتنی بر عملکرد شده است. در این آیین نامه ها بر اساس تغییرشکل های غیرارتجاعی ...
15 صفحه اول: the effect of sericin levels (silk glue protein) on rate of in vitro maturation, fertilization and culture of sheep oocytes
هدف از آزمایش اول بررسی اثر سطوح مختلف سریسین [0 (control), 0.1, 0.5, 1.0, 2.5 %] افزوده شده به محیط , ivm بر cumulus cell expansion، بلوغ هسته و توسعه متوالی جنین، در گوسفندان نژاد سنجابی در فصل تولید مثلی می باشد. از سرگیری میوز به وسیله خارج شدن اولین پولار بادی اندازه گیری و هم چنین درصد رسیدن جنین های دو سلولی به مرحله کلیواژ و بلاستوسیت نیز به عنوان نشانه ای از میزان شایستگی توسعه اولیه ج...
Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 115- 115
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023