Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method

نویسندگان

چکیده مقاله:

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activity level equal to 0.5 mCi) iodine-125 brachytherapy source, we used MCNPX 2.6 code and TG-43U1 protocol, and we used ORNL phantom. Treatment plan included 76 sources consisting iodine-125 radioactive, once placed in the form of seeds and once applied in the form of beads in three initial volume: 30.02, 38.01 and 52.01 cm3 and three different time steps were placed in prostate phantom. Three-time steps were investigated, including the moment after placing, the zero days and thirty days after placing. In the first step, the obtained dose of radiation in three different prostate volumes, for both seed distribution and bead distribution in healthy and cancerous tissue, was calculated. In the second step, position of the sources was relocated from the assumption, and causes a change in dose distribution. Considering the movements in 3 directions of left-to-right (1.8 mm), intra-exterior (2.1 mm), up-down (3.4 mm) after implantation the equivalent dose was calculated. The maximum uncertainty of received dose in a prostate with seed implanted sources and the volume of 52.01 cm3 and it was reported as +20%. At the third step, in addition to the change in the location of sources, inflation rate of 12% was observed in comparison with the primary volume at the first step of treatment process which resulted in a smaller dose rather than the previous stage. In this treatment plan, relocating of the sources and 12% inflation of the tumor were analyzed. Uncertainty of source relocating was calculated as ±20% in zero-day of positioning. Also, 12% inflation of the tumor and source relocation after 30 days, in a prostate with the volume of 58.25 cm3 curing by point sources, shown 21.04% reduction in received dose for healthy and cancer tissues since the moment of placing. The maximum error of MCNPX code was calculated 0.03%.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the absorbed dose rate of all rays emitted from the 252Cf brachytherapy source by the Monte Carlo method

The 252Cf brachytherapy source is a spontaneous fission decay source, which is used as a neutron-emitting source. In addition to neutrons emitted from this source, gamma rays are also emitted with the average energy of 1 MeV. In this study, using the Monte Carlo N-Particle code (MCNPX), the absorbed dose rates of the neutrons, the primary gamma and the secondary gamma that generated by thermal ...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method

 Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.

Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...

متن کامل

Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...

متن کامل

Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method

Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher-Green type applicator with the uterine tandem was fixed at the bottom of the phantom reproducing a typical geomet...

متن کامل

Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method

Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherap...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  203- 212

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023