Are Radiation Exposure Levels Used in Cardiology Dangerous?

نویسندگان

  • F. Nowrouz-Alizadeh Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • M. Haghani The Center for Radiological Research, Shiraz University of Medical Sciences, Shiraz, Iran
  • M. M. Movahhedi Faculty Member of Medical Engineering, Department of Medical Physics and Medical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
  • N. Omidifar Pathology Resident, Pathology Department, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
  • R. Faghihi Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • S. M. Hashemi The Center for Radiological Research, Shiraz University of Medical Sciences, Shiraz, Iran
  • S. M. J. Mortazavi Professor of Medical Physics, Department of Medical Physics and Medical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
  • S. Masoumi The Center for Radiological Research, Shiraz University of Medical Sciences, Shiraz, Iran
  • S. Mehdizadeh Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
چکیده مقاله:

Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determined by a wide range of factors such as clinical problems to be treated, the interventional technique to be used, the x-ray system employed, experience of the cardiologist, the protective measures taken as well as their use during the examination.Objective: To measure the dose received by 22 cardiologists, radiology residents, radiologic technologists and nurses during interventional cardiology examinations performed in various teaching hospitals affiliated to Shiraz University of Medical Sciences.Methods: The radiation dose was basically measured by thermoluminescence dosimeters (TLD). Other personal dosimetry devices such as film badges and pen dosimeters were also used. According to IAEA guidelines, the dosimeter should be worn under the lead apron (at waist level) for estimating the effective dose but due to high workload in interventional radiology and since the areas of the body which are not protected by the apron receive much higher radiation doses, in this study an additional dosimeter was used over the apron (at collar level).Results: The mean±SD monthly dose recorded by dosimeters of cardiologists over the apron at collar level was 912.1±224.4 (range: 660.8–1176.4) μGy; hands received doses up to 9674.4 μGy month−1 as recorded by TLD chips.Conclusion: The annual effective dose received by interventional cardiologists who use standard lead aprons hardly reaches the occupational exposure dose limit of 20 mSv/y.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

are radiation exposure levels used in cardiology dangerous?

background: the number of interventional cardiology procedures performed has increased rapidly over the past years. while these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. the dose received by the cardiologist during interventional cardiology procedures is determi...

متن کامل

Controlling radiation exposure in interventional cardiology.

T he idiom " double-edged sword " describes the use of ionizing radiation in the field of medicine. Medical radiation from x-rays and nuclear medicine is the largest man-made source of radiation in Western countries and although it has benefited patients there is an associated liability or health risk that is unavoidable. A 2009 report by the National Council on Radiation Protection and Measure...

متن کامل

Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania

Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optim ization techniques among interventional cardiologists in Lithuania. Interventional card...

متن کامل

Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania.

Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optimization techniques among interventional cardiologists in Lithuania. Interventional cardi...

متن کامل

International project on individual monitoring and radiation exposure levels in interventional cardiology.

Within the Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR), a new International Atomic Energy Agency initiative, a Working Group on interventional cardiology, aims to assess staff radiation protection (RP) levels and to propose an international database of occupational exposures. A survey of regulatory bodies (RBs) has provided information at the country ...

متن کامل

Personnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends

ABSTRACT Background: Monitoring internal exposure of individuals handling significant amounts of iodine-125 (I-125) for iodination is of great importance. These individuals are potentially exposed to external contamination, and internal contamination through inhalation, ingestion and intact skin absorption, to I-125. Considering radiological toxicity of this radionuclide its monitoring in the w...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 3

صفحات  -

تاریخ انتشار 2012-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023