Application of Imidazolium based ionic liquid Nano-emulsions for the removal of H2S from crude oil
نویسندگان
چکیده مقاله:
Hydrogen sulfide is one of the most dangerous contaminants in crude oil and natural gas that have to be removed prior to the transfer and refining. In this study, hydrophobic ionic liquid, i.e. 1-ethyl-3-methylimidazolium methylflour, [EMIM] [NTf2], was used as scavenger for the reduction of the H2S. Due to its ionic nature, [EMIM] [NTf2] forms nanoemulsion in crude oil media and hence can dissolve H2S polar molecules within its core. Determination of H2S was carried out using well-known UOP-163 potentiometric titration. The effect of [EMIM] [NTf2] on the H2S concentration was investigated via two methods: dynamic and static. Dynamic method performed to check the effect of required dosage for the removal of H2S and also investigate effect of contact time. In the static methods a number of tests were designed with central composite design (CCD) to investigate the effect of three factors, i.e. scavenger dosage, reaction time and temperature, as well as the interaction between them on the concentration of H2S via response surface methodology (RSM). Among these three factors and according to the F value, scavenger dosage and time had the great influence on the response, respectively. In comparison, temperature had very low effect on the response. The resulted model was also statistically significant with non-important LOF index.
منابع مشابه
an application of equilibrium model for crude oil tanker ships insurance futures in iran
با توجه به تحریم های بین المملی علیه صنعت بیمه ایران امکان استفاده از بازارهای بین المملی بیمه ای برای نفتکش های ایرانی وجود ندارد. از طرفی از آنجایی که یکی از نوآوری های اخیر استفاده از بازارهای مالی به منظور ریسک های فاجعه آمیز می باشد. از اینرو در این پایان نامه سعی شده است با استفاده از این نوآوری ها با طراحی اوراق اختیارات راهی نو جهت بیمه گردن نفت کش های ایرانی ارائه نمود. از آنجایی که بر...
application of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولnobel method for toluene removal from air based on ionic liquid modified nano-graphen
the aim of this study was to investigate the removal of toluene from air through nano-graphene modified by ionic liquid (ng-il). the batch adsorption experiments in glass bottle of gas chromatography equipped with flame ionization detector (gc-fid) were used. graphene ultrahigh-quality synthesized by substrate-free gas-phase method in a single step and graphene sheets were deposited with ionic-...
متن کاملFeasibility of low frequency ultrasound for water removal from crude oil emulsions.
The feasibility of indirect application of low frequency ultrasound for demulsification of crude oil was investigated without using chemical demulsifiers. Experiments were performed in an ultrasonic bath with frequency of 35 kHz. Synthetic emulsions with water content of 12%, 35% and 50% and median of droplet size distribution (DSD), median D(0.5), of 5, 10 and 25 μm were prepared from crude oi...
متن کاملthe application of multivariate probit models for conditional claim-types (the case study of iranian car insurance industry)
هدف اصلی نرخ گذاری بیمه ای تعیین نرخ عادلانه و منطقی از دیدگاه بیمه گر و بیمه گذار است. تعین نرخ یکی از مهم ترین مسایلی است که شرکتهای بیمه با آن روبرو هستند، زیرا تعیین نرخ اصلی ترین عامل در رقابت بین شرکتها است. برای تعیین حق بیمه ابتدا می باید مقدار مورد انتظار ادعای خسارت برای هر قرارداد بیمه را برآورد کرد. روش عمومی مدل سازی خسارتهای عملیاتی در نظر گرفتن تواتر و شدت خسارتها می باشد. اگر شر...
15 صفحه اولCovalent Modification of Glassy Carbon Electrode with an Imidazolium based Methoxysilyl Ionic Liquid Nanoparticles: Application in Determination of Redox System
Glassy carbon (GC) is the most commonly used carbon-based electrode in the analytical laboratory. Because of the high background current and low electrode response, modification of this electrode can be done by various materials and techniques. An ionic liquid (IL), 1-methyl-3-(3-trimethoxysilyl propyl) imidazoliumbis (trifluoromethylsulfonyl) imide, was covalently cross linked onto the GC surf...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 2 شماره 3
صفحات 68- 74
تاریخ انتشار 2015-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023