Analysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine

نویسندگان

  • A. Darijani the Department of Electrical Engineering, Faculty of Engineering, the University of Isfahan
  • A. Kiyoumarsi the Department of Electrical Engineering, Faculty of Engineering, the University of Isfahan
  • B. Mirzaeian Dehkordi the Department of Electrical Engineering, Faculty of Engineering, the University of Isfahan
  • H. A. Lari the Department of Electrical Engineering, Faculty of Engineering, the University of Isfahan
  • S. M. Madani the Department of Electrical Engineering, Faculty of Engineering, the University of Isfahan
چکیده مقاله:

In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with different pole-slot combinations are designed. Average torque, torque ripple and cogging torque are evaluated based on finite element method. The combination with best performance is chosen and with the analysis of variation of effective parameters on cogging torque, and introducing a useful method, an improved design of the PMSG with lowest cogging torque and maximum average torque is obtained. The results show a proper performance and a correctness of the proposed method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of a Permanent Magnet Synchronous Generator for a Vertical Axis Wind Turbine

Different types of permanent magnet generators for wind power application have been subject of research during last two decades. In this thesis different topologies of electrical generators have been investigated for small scale vertical axis wind turbine application. A two stage induction generator is proposed as a alternative solution with respect to the cost of such a system. However, a bigg...

متن کامل

Direct Liquid Cooling for an Outer-Rotor, Direct- Drive, Permanent-Magnet Synchronous Generator for Wind Farm Applications

Wind power is experiencing steady growth, and wind turbine technologies are continually developing. Currently, power ratings of up to 20 MW are being considered for future wind farms. Offshore applications, which call for the largest and most powerful wind turbines, demand a higher standard of reliability and maintainability. Because they offer better overall efficiencies and higher reliability...

متن کامل

Design of a Permanent-Magnet Synchronous Generator for a 2 MW Gearless Horizontal-Axis Wind Turbine According to its Capability Curves

Permanent-Magnet Synchronous Generators (PMSGs) exhibit high efficiency and power density, and have already been employed in gearless wind turbines. In the gearless wind turbines, due to the removal of the gearbox, the cogging torque is an important issue. Therefore, in this paper, at first, design of a Permanent-Magnet Synchronous Generator for a 2MW gearless horizontal-axis wind turbine, acco...

متن کامل

Wind Turbine Driven by Permanent Magnet Synchronous Generator

A permanent magnet synchronous generator (PMSG) variable speed wind turbine connected to an electrolyzer and a battery model system is presented in this paper. Hydrogen gas could be produced from the model system, when a variable wind speed is applied to the PMSG driven variable wind turbine. The simulation results presented shows the nature of some of the variables of the PMSG wind driven turb...

متن کامل

Design of High-Efficiency and Low-Cost Six-Phase Permanent Magnet Synchronous Generator for Direct-Drive Small-Scale Wind Power Application

Permanent magnet synchronous generators (PMSG) have a huge potential for direct-drive wind power applications. Therefore, optimal design of these generators is necessary to maximize their efficiency and to reduce their manufacturing cost and total volume. In this paper, an optimal design of a six-phase 3.5 KW direct-drive PMSG to generate electricity for domestic needs is performed. The aim of ...

متن کامل

Dynamic Analysis of Grid Connected Wind Turbine with a Permanent Magnet Synchronous Generator during Fault Conditions

The use of wind turbines is increasing at very high rates in many countries around the world. Studies to evaluate the impact of connecting these new generation units to the existing power systems must be done. This paper proposes a wind energy conversion system for a grid connected permanent magnet synchronous generator (PMSG) and power electronic converter system. The model includes a PMSG mod...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 10  شماره 4

صفحات  324- 332

تاریخ انتشار 2014-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023