An iterative method to estimate x-ray attenuation coefficients in computed tomography
نویسندگان
چکیده مقاله:
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (DECT), determination of electron density and dose calculation in treatment planning system. The aim of this paper is to calibrate the CT system, to calculate Compton scattering and photoelectric effect by an iterative method. Materials and Methods: Chemical compounds with known effective atomic number and electron density were scanned at 80, 110, and 130kVp. HU values of these compounds were used to calculate Compton scattering and photoelectric effect by an iterative method. The calculated coefficients were used to estimate the HU values of liquid samples and solid rods made of polymers, to evaluate our findings Results: The coefficients were found up to the fifth order of iteration and the coefficients were found to match the data with 95% confidence at 80, 110, and 130 kVp. The maximum deviation between the calculated and actual HU values were less than 3% for liquid and solid samples at these kVp values. Conclusion: Calibration of CT system by known chemical samples, by using iterative method of data analysis may give very accurate idea about the x-ray attenuation coefficients of samples. Results of this study may be used in tissue characterization by DECT inversion, and to estimate electron density and dose distribution in treatment planning systems
منابع مشابه
Evaluation of effect of gold nanorods and spherical gold nanoparticles of different sizes on X-ray attenuation in computed tomography
Introduction: To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agent for CT imaging and therapeutics. This study was designed to evaluate any effect on X-ray attenuation that might result from using GNPs with a variety of size, surface chemistries and shapes. Materials and Methods: Spherical GNPs and gold nanorod...
متن کاملRandomized Iterative Reconstruction for Sparse View X-ray Computed Tomography
With the availability of more powerful computers, iterative reconstruction algorithms are the subject of an ongoing work in the design of more efficient reconstruction algorithms for X-ray computed tomography. In this work, we show how two analytical reconstruction algorithms can be improved by correcting the corresponding reconstructions using a randomized iterative reconstruction algorithm. T...
متن کاملX-ray computed tomography.
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictio...
متن کاملX-ray micro-computed tomography
Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitablecontrast agent, blood vessels have beenimaged and analysed quantitatively such asblood volume and vessel sizes on embryosof ages 14.5 to 16.5 days old. The advantageof using this imaging modality is that it hasprovide...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملPorosity Measurement Method by X-ray Computed Tomography
Therefore, the new method, called the grey level method, which reflects the phenomenon of image processing and computation of ration between the volume of voids and the total volume of the entire sample, was considered and improved in term of image noise and artifacts. The volumes of 2D CT image as a surface are achieved by means of integrating the surface with operations relating to image hist...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 348- 348
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023