An Intelligent Protection Method for Multi-terminal DC Microgrids Using On-line Phaselet, Mathematical Morphology, and Fuzzy Inference Systems

نویسندگان

  • Dodangeh, Mostafa Department of Electrical Engineering, Imam Khomeini International University
چکیده مقاله:

In this paper, a new method for fault detection, location, and classification in multi-terminal DC microgrid (MTDC) is proposed. MTDC grids have expanded due to some issues such as the expansion of DC resources, loads, and aims to increase power quality. Diagnosing the types and location of faults is important to continue the service and prevent further outages. In this method, a circuit kit is connected to the grid. In fault time, the fault in the network is detected by passing the current through the connected kits and measuring the traveling waves derived from the fault current as well as applying it to a mathematical morphological filter. Determining the location of the fault is done using circuit equations and current calculations. Phaselet output and fuzzy inference systems are used to determine the type of faults. The presented method was tested in an MTDC microgrid connected to renewable and energy storages with many faults. The results show the ability of the proposed method. The error of the proposed fault location method is less than 7%. This method is resistant towards the change in sampling frequency (between 500 Hz and 50 kHz), fault resistance (up to 125 ohms), and loading (up to 120% of the nominal load); it acts very well in high impedance faults.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distributed Optimization Method for Intelligent Control of DC Microgrids

Most of the distributed energy resources, loads and energy storage systems in a DC microgrid are equipped with power electronic converters. With the integration of advanced power electronics devices, a microgrid is able to utilize a broader range of technologies in its design and operation. A key feature of power electronic converter based systems is the ability to direct energy flow within a s...

متن کامل

Fault detection, classification and location methodology for solar microgrids using current injection, online phaselet transform, mathematical morphology filter and signal energy analysis

In this paper, a new method for detection and fault location and classification in MTDC solar microgrid is presented. Some issues such as expanding renewable energy sources and DC loads and efforts to increase power quality and reduce the environmental impact of electricity generation have led to the expansion of solar networks. Identifying the types and locations of faults is important to ensu...

متن کامل

An Intelligent Machine Learning-Based Protection of AC Microgrids Using Dynamic Mode Decomposition

An intelligent strategy for the protection of AC microgrids is presented in this paper. This method was halving to an initial signal processing step and a machine learning-based forecasting step. The initial stage investigates currents and voltages with a window-based approach based on the dynamic decomposition method (DDM) and then involves the norms of the signals to the resultant DDM data. T...

متن کامل

Multi-Terminal DC System line Protection Requirement and High Speed Protection Solutions

For long distance and high power transmission, high-voltage direct current (HVDC) transmission is a preferred solution due to its technical and economic advantages. A multi-terminal HVDC (MTDC) transmission system either based on voltage source converters (VSC) or line-commutated converters (LCC) has also been introduced recently. With the development of fast and high breaking capability HVDC c...

متن کامل

Fuzzy Inference Method for Intelligent Artificial System

A fuzzy control system which is a typical system utilizing fuzzy model is mainly using the Max-Min CRI (Compositional Rule of Inference) method by Zadeh and Mamdani for fuzzy inference. But the Max-Min CRI method suffers from drawbacks including: error-prone weighting strategy, inefficient compositional rule of inference, and subjective formulation of membership functions. Because of these prob...

متن کامل

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 2

صفحات  12- 25

تاریخ انتشار 2022-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023