An Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India
نویسندگان
چکیده مقاله:
Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Linearity of time (sec), linearity of current (mA), output reproducibility, table dose (μGy/mAs), peak voltage (kVp) accuracy, and 16 essential safety parameters of 135 X-ray machines were considered in this study. A battery-operated dosimeter and wide-range digital kVp meter were used to measure output radiation and effective peak potential of X-ray tube. Data analysis was performed using SPSS software to obtain the mean, standard deviation, and coefficient of variation. Results: Among different electronic parameters, 59.2% linearity of time, 82.6% linearity of current, 89.7% kVp accuracy, 35.1% output reproducibility, and 92.8% table dose were beyond the acceptable limits. Based on 16 essential safety parameters, it was observed that 98.7% of X-ray machines did not receive proper quality assurance test, 1.9% of the installations employed lead-line patient entrance doors, 46.8% of the machines were operated without any protective barriers and 83.1% of the units were operated without personnel monitoring service. Conclusion: The present study had concluded with more problems than the previous studies in different parts of the world in this regard. Due to the absence of proper quality control (QC) programs, many installations did not follow standard installation guidelines. The authors recommended that proper QC should be implemented by the frequent monitoring of each and every diagnostic X-ray installation.
منابع مشابه
Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملLocal Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...
متن کاملRadiation attenuation properties of shields containing micro and Nano WO3 in diagnostic X-ray energy range
Background: It has recently been shown that the particle size of materials used for radiation shielding can affect the magnitude of radiation attenuation. Over the past years, application of nano-structured materials in radiation shielding has attracted attention world-wide. The purpose of this study was to investigate the shielding properties of the lead-free shields containing micro and nano-...
متن کامل[Report based on Fiscal 2010 Diagnostic X-ray Equipment Questionnaire Survey (conditions of X-ray units and similar equipment)].
On X-ray diagnostic technology, it is important to grasp a change of the X-ray high-voltage equipment and radiographic technique factors. The 1st questionnaire was performed in 1974, and it carried out after that every five years, and conducted 8th investigation. As a result, we requested 656 institutions and got a reply from 103 institutions. The response rate was 15.7%. For X-ray high-voltage...
متن کاملAn upgraded x-ray spectroscopy diagnostic on MST.
An upgraded x-ray spectroscopy diagnostic is used to measure the distribution of fast electrons in MST and to determine Z(eff) and the particle diffusion coefficient D(r). A radial array of 12 CdZnTe hard-x-ray detectors measures 10-150 keV Bremsstrahlung from fast electrons, a signature of reduced stochasticity and improved confinement in the plasma. A new Si soft-x-ray detector measures 2-10 ...
متن کاملPerformance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea
Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 17 شماره 4
صفحات 273- 281
تاریخ انتشار 2020-07-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023