An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

نویسندگان

  • F Seif Arak University of Medical Sciences
چکیده مقاله:

Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values of calculated linear attenuation coefficient with this new method are in acceptable range. Also, the linear attenuation coefficient decreases slightly as the thickness of attenuating filter (Cerrobend or mercury) increased, so the procedure of linear attenuation coefficient variation is in agreement with other documents. The results showed that the attenuation ability of mercury was about 1.44 times more than Cerrobend. Conclusion: The method that was introduced in this study for linear attenuation coefficient calculation is general enough to treat beam modifiers with any shape or material by using the same formalism; however, calculating was made only for mercury and Cerrobend attenuator. On the other hand, it seems that this method is suitable for high energy shields or protector designing.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

an analytical-empirical calculation of linear attenuation coefficient of megavoltage photon beams

background: in this study, a method for linear attenuation coefficient calculation was introduced. methods: linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. the calculation was done for cerrobend as a common radiotherapy modifier and mercury. results: the valu...

متن کامل

An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

BACKGROUND In this study, a method for linear attenuation coefficient calculation was introduced. METHODS Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. RESULTS The val...

متن کامل

Investigation of the effects of a carbon-fiber tabletop on the surface dose and attenuation dose for megavoltage photon beams

Background: Multiple beams are generally used with an increased possibility that the beam axis intersects the treatment table. Treatment tabletops are commonly made of carbon fiber due to its high mechanical strength and rigidity, low specific density, extremely light and low radiation beam attenuation properties. Purpose of this paper is investigated the dose changes in the buildup region and ...

متن کامل

Application of spherical diodes for megavoltage photon beams dosimetry.

PURPOSE External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A high uniformity in angular response is also a very important feature in a detec...

متن کامل

On few-view tomographic reconstruction with megavoltage photon beams.

Currently portal imaging devices are used to obtain information on patient localization during radiation therapy treatments. Such obtained information is two dimensional in nature, limited to the plane of the captured image. It has been proposed that megavoltage computed tomography images be reconstructed to overcome this limitation. This study explores the feasibility of reconstructing tomogra...

متن کامل

Intermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments

The goal of this study is to evaluate the effects of intermediate megavoltage (3-MV) photon beams on SBRT lung cancer treatments. To start with, a 3-MV virtual beam was commissioned on a commercial treatment planning system based on Monte Carlo simulations. Three optimized plans (6-MV, 3-MV and dual energy of 3- and 6-MV) were generated for 31 lung cancer patients with identical beam configurat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 3

صفحات  -

تاریخ انتشار 2017-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023