Advanced Oxidation Process Based Sulfate Radical (AOP-SR) in a UV Reactor to Remove Pentachlorophenol from Aqueous Media

نویسندگان

  • Asgari , Ghorban Social Determinants of Health Research Center (SDHRC), Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Science, Hamadan, Iran-Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
  • Jamshidi , Reza Master of Environmental Health Engineering, , School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
  • Samargandi , Mohammad Reza Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
  • Seid-Mohammadi , Abdolmotaleb Social Determinants of Health Research Center (SDHRC), Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Science, Hamadan, Iran-Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
چکیده مقاله:

Background & Objectives: In recent years, due to water shortages and rapid industrial growth, the treatment and reuse of industrial wastewater has become of great importance. Phenol and its derivatives can be mentioned as wastewater pollutants that have a destructive effect on the environment. Pentachlorophenol (PCP) is one of these derivatives that may be carcinogenic to humans, and wastewater treatment containing PCP is required. Therefore, the aim of this study was to remove PCP from aqueous media. Materials and Methods: Effective operating parameters such as initial PCP concentration (25, 50, 100, and 150 mg/L), persulfate concentration (25, 50, 75, and 100 mg/L), solution pH (5, 7, 9, and 11), and reaction time (10, 20, 30, and 40 min) were investigated. After the removal of PCP, an experimental design based on an orthogonal array using the Taguchi method was proposed. Results: Based on the results, 98.78% of PCP in the optimal conditions (initial concentration of PCP of 25 mg/L, concentration of sodium sulfate (Na-PS) of 20 mg/L, pH = 11, and reaction time of 40 min) was removed. In this process, the COD and TOC removal rates were 82.3% and 61%, respectively. Analysis of variance (ANOVA) showed that persulfate is the most effective factor in the removal of PCP in the persulfate/UV process. Conclusion: Persulfate/UV processes as an advanced oxidation process, powerful and environmentally friendly, can be used in wastewater treatment containing phenolic compounds, including PCP.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aniline Degradation Using Advanced Oxidation Process by UV/Peroxy Disulfate from Aqueous Solution

This study is focused on removing toxic aniline from aqueous solutions using advanced oxidation process by UV/ peroxy disulfate. In this study, the effect of various parameters including pH (3-9), the level of radiation (ultraviolet 30 watt lamp, number 2-5), peroxy disulfate dose (0.02 – 0.08 mol/l) and the initial concentration (20 – 100 mg/l) at different contact times (10 – 60 min) on the e...

متن کامل

UV/ H2O2 Advanced Oxidation Process for Simultaneous Removal of NO and SO2: A Review

This study presents a review on advanced oxidation processes (AOP) for simultaneous removal of NO and SO2. AOP is based on using a strong oxidant such as ozone and H2O2 which is able to generate highly reactive intermediates. The pollutant will be oxidized and removed by these intermediates. In recent years, AOP has been considered as an effective and attractive technology in the field of flue ...

متن کامل

Advanced Oxidation Process for Phenol Degradation By UV/TiO2 In Aqueous Solutions

Phenolic compounds are widely used in industries and other daily life for various purposes and enter in the industrial effluent and ultimately the final disposal of this effluent which contain phenol compounds are different water bodies which may get contaminated through the continuous disposal of the these effluents. Highly toxicity and carcinogenicity of these compounds can cause considerable...

متن کامل

Application of Electro-Fenton (EF) Process to the Removal of Pentachlorophenol from Aqueous Solutions

Pentachlorophenol (PCP) is a very hazardous compound which enters into the environment by industries such as refineries and petrochemicals. As its biological degradation is very slow, this use may cause the pollution of soils and groundwater; with the recent emergence of pentachlorophenol contamination as an important drinking water quality issue, finding an easy, economical, and useful method ...

متن کامل

Evaluation of UV/H2O2 advanced oxidation process (AOP) for the degradation of acid orange7 and basic violet 14 dye in aqueous solution

I. Introduction Extensive usage of dyestuffs and its disposal are the important sources for the today's environmental contamination. Different types of chemical and physical processes such as chemical coagulation, activated carbon adsorption are used for pollutant removal in the textile industrial wastewater, but they just transfer contaminants from one phase to another that needs further and u...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 2

صفحات  223- 238

تاریخ انتشار 2022-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023