Advanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries
نویسندگان
چکیده مقاله:
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration cycle compressors is usually provided by gas turbines. The low efficiency of gas turbines and the excessive power required for running the CRS compressors have made it crucial to investigate different means to decrease the energy consumption of this cooling system. The waste heat of gas turbines flue gas can be recovered and utilized as the heating source for running an absorption refrigeration system (ARS) to provide part of the needed cooling load; hence, a hybrid compression absorption refrigeration system (HCARS) is launched. In this work, the application of HCARS is extended to the Fajr-e-Jam gas refinery currently operating with a CRS, and an advanced exergetic analysis of the proposed ARS is performed to further improve the proposed system. The effect of different variables on the performance of the proposed HCARS is also inspected. The proposed system and these analyses are novel for the gas refinery dew point control unit. Real CRS operational data are utilized in all the investigations, and proper means are presented for the validation of the simulation results. The proposed system resulted in 63% additional cooling capacity of the HCARS (12550 KW) in comparison to the current CRS (7670 kW) for the equal natural gas consumption, which overall saves about 50000 SCMD of natural gas. Based on the exergy analysis of all the equipment, the exergy efficiency of the proposed ARS is 0.155. In addition, the parametric study of the effects of the gas turbine flue gas exit temperature and flow rate, ambient temperature, partial load operation of CRS, absorption solution flow rate, and concentration on the HCARS performance is carried out. These studies should provide the information needed for operating the proposed system in different situations.
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
elimination of btex , voc vapors from glycol in gas hydrant unit
during natural gas processing, water in natural gas may cause to hydrates formation in pipelines which may lead to serious damages to process equipments. given the problems raised by present of water in natural gas, glycol solvent uses to remove water.in contact of glycol with gas always an amount of btex and voc absorb along with water, which on glycol recovery process, these substances separa...
15 صفحه اولanalysis of power in the network society
اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...
15 صفحه اولMulti-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries
The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...
متن کاملMulti-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries
The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...
متن کاملDynamic Simulation of Distillation Sequences in Dew Pointing Unit of South Pars Gas Refinery
The understanding of the dynamic behavior of distillation columns has received considerable attention because distillation is one of the most widely used unit operations in chemical process industries. This paper reports a dynamic simulation study of the possible distillation columns sequences of Dew pointing unit in the second phase of South Pars Gas Refinery. In this unit, three columns are u...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره 3
صفحات 32- 52
تاریخ انتشار 2018-07-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023