Accuracy of Amniotic Fluid Index and Single Deepest Pocket Measurements in Predicting the Outcomes of Prolonged Pregnancies
نویسندگان
چکیده مقاله:
Introduction: Two techniques for sonographic evaluation of amniotic fluid are Amniotic Fluid Index (AFI) and Single Deepest Pocket (SDP). In this study,we aimed to determine the accuracy of AFI and SDP in predicting prolonged pregnancy outcomes. Methods: In this prospective, double-blinded, cohort study, 362 women with more than 40 weeks of gestational age were evaluated. Both AFI and SDP methods were used for all patients. Pregnancy-related outcomes and complications including meconium-stained amniotic fluid (MSAF), 5-minute Apgar score, Neonatal Intensive Care Unit (NICU) admission, necessity of cesarean section, and mortality rate were evaluated. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were also calculated. Results:Sensitivity and specificity of AFI in the diagnosis of MSAF were 68% and 47%, respectively; the rates were higher than those of SDP. Compared to SDP, AFI was more sensitive for predicting the necessity of cesarean section (85% vs. 68%). No association was found between abnormal 5-minute Apgar score and abnormal AFI or SDP. Conclusion: Compared to SDP, AFI is a better method for predicting MSAF and necessity of NICU admission or caesarian section.
منابع مشابه
The evidence for abandoning the amniotic fluid index in favor of the single deepest pocket.
This study assessed whether the amniotic fluid index (AFI) or the single deepest pocket (SDP) is the best technique to estimate amniotic fluid volume. The AFI and SDP were compared to a dye-determined or directly measured amniotic fluid volume. A PUBMED search from 1990 to 2006 was conducted using the search terms "single deepest pocket" or "largest vertical pocket" or "maximum vertical pocket"...
متن کاملThe maximal vertical pocket and amniotic fluid index in predicting fetal distress in prolonged pregnancy.
OBJECTIVE To determine cut-off values for amniotic fluid volume (AFV) predictive of fetal distress in pregnancies 40 weeks or longer, assessed using both amniotic fluid index (AFI) and height of the of maximal vertical pocket (MVP). METHODS Amniotic fluid index and MVP were evaluated in 100 women with pregnancies of 40 or more weeks and intact membranes using a 3.5-MHz linear transducer less ...
متن کاملReproducibility of measuring amniotic fluid index and single deepest vertical pool throughout gestation.
OBJECTIVE The aim of this study is to assess the intraobserver and interobserver reproducibility of measurement of amniotic fluid index (AFI) and single deepest vertical pool (SDVP), also known as the maximal vertical pocket. METHODS A total of 175 fetuses were evaluated. For each fetus, two observers acquired duplicate sets of AFI and SDVP. Measurement differences were expressed as actual an...
متن کاملthe effect of task complexity on efl learners’ written task performance in terms of accuracy and complexity
هدف اصلی این تحقیق بررسی تاثیر افزایش میزان پیچیدگی تکالیف مکالمه محور بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 15 الی 18 سال درسطح pre-intermediate از طریق petو vhs تست به عنوان شرکت کنندگان در تحقیق انتخاب شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی دو تکلیف ساده و پیچیده را طی 2 جلسه انجام...
the effects of time planning and task complexity on accuracy of narrative task performance
هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...
perinatal outcomes of pregnancies with borderline versus normal amniotic fluid index
background: amniotic fluid is an indicator of placental function on the fetal development. the amniotic fluid index is the most commonly used method of measuring amniotic fluid. objective: the purpose of this study was to compare the pregnancy outcomes of a borderline versus normal afi. materials and methods: this cross-sectional study was carried out on a total of 235 pregnant women referred t...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره Abstract
صفحات 5- 5
تاریخ انتشار 2014-10-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023