A study on slab-wooden dust-slab phantom for the development of thorax phantom

نویسندگان

  • Krishna Lal Gupta Professor Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore, Madhya Pradesh - 453111
  • Om Prakash Gurjar Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore (MP), India
  • Priyusha Bagdare PhD Scholar School of Studies in Physics, Vikram University, Ujjain 456010, India
  • Sanjay Kumar Ghosh Professor & Head School of Studies in Physics Vikram University, Ujjain (M.P.) 456001
  • Saurabh Karnawat MD Scholar Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore, Madhya Pradesh - 453111
  • Swati Dubey Associate Professor School of Studies in Physics Vikram University, Ujjain (M.P.) 456001
  • Virendra Bhandari Professor Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore, Madhya Pradesh - 453111, India [email protected] +91-9893115337
چکیده مقاله:

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: The density of SP34 slab, wooden dust of pine, and thoracic region of 10 patients were calculated using computed tomography (CT) images. The depths of isodose lines were measured for 6 MV beam on the CT images of the chest, SP34 slab phantom, and SWS phantom. Dose calculation was performed at the depths of 2, 13, and 21 cm in both phantoms. Furthermore, patient-specific quality assurance (QA) was implemented using both phantoms. Results: The mean densities of the lung, SP34 slabs, and wooden dust were 0.29, 0.99, and 0.27 gm/cc respectively. The mean depths of different isodose lines in the SWS phantom were found to be equivalent to those in actual patients. Furthermore, the percentage variation between the planned and measured doses was higher in the SWS phantom as compared to that in the SP34 phantom. Furthermore, the percentage variation between the planned and measured doses in patient-specific QA was higher in the SWS phantom as compared to that in the SP34 phantom. Conclusion: As the findings indicated, the density and isodose depth profiles of the SWS phantom were equivalent to those of the actual thoracic region of human.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Dosimetric Study on Slab-pinewood-slab Phantom for Developing the Heterogeneous Chest Phantom Mimicking Actual Human Chest

The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT...

متن کامل

Impact of range straggling and multiple scattering on proton therapy of brain, using a slab head phantom

Background: The advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. Materials and Methods: In this study, the Monte Carlo MCNPX code has been used to simulate a slab head phantom ...

متن کامل

Influence of the PMMA and the ISO Slab Phantom for Calibrating Personal Dosemeters

INTRODUCTION Wide agreement has been reached among the main Bodies and Organizations involved in standardization of radiation protection to define as operational quantity for individual monitoring of external exposure, the personal dose equivalent, Hp(d) (1,2,3). However, as Hp(d) is defined in the human body, it is not a measurable quantity. In practice, it has to be estimated from the indicat...

متن کامل

the effect of consciousness raising (c-r) on the reduction of translational errors: a case study

در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...

15 صفحه اول

impact of range straggling and multiple scattering on proton therapy of brain, using a slab head phantom

background: the advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. materials and methods: in this study, the monte carlo mcnpx code has been used to simulate a slab head phantom ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 2

صفحات  71- 77

تاریخ انتشار 2018-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023