A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

نویسندگان

  • A Esmaili Torshabi PhD, Faculty of Sciences and Modern Technologies Graduate University of Advanced Technology Haftbagh St. Kerman Iran
  • S Parande MSc, Faculty of Sciences and Modern Technologies Graduate University of Advanced Technology Haftbagh St. Kerman Iran
چکیده مقاله:

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DIR-lab group were utilized. Four implemented registration algorithms as 1) Original Horn-Schunck, 2) Inverse consistent Horn-Schunck, 3) Original Demons and 4) Fast Demons were implemented by means of DIRART software packages. Then, the calculated vector fields are processed to reconstruct 4DCT images at any desired time using optical flow based on interpolation method. As a comparative study, the accuracy of interpolated image obtained by each strategy is measured by calculating mean square error between the interpolated image and real middle image as ground truth dataset.Results: Final results represent the ability to accomplish image interpolation among given two-paired images. Among them, Inverse Consistent Horn-Schunck algorithm has the best performance to reconstruct interpolated image with the highest accuracy while Demons method had the worst performance.Conclusion: Since image interpolation is affected by increasing the distance between two given available images, the performance accuracy of four different registration algorithms is investigated concerning this issue. As a result, Inverse Consistent Horn-Schunck does not essentially have the best performance especially in facing large displacements happened due to distance increment.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a study on robustness of various deformable image registration algorithms on image reconstruction using 4dct thoracic images

background: medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. this information may be useful for better diagnosis of possible lesions or better tumor delineation at radiation treatment. to do this, deformable image registration algorithms are mainly utilized to perform image interpolation ...

متن کامل

Evaluation of various deformable image registration algorithms for thoracic images

We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical lan...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Implementation and evaluation of various demons deformable image registration algorithms on a GPU.

Online adaptive radiation therapy (ART) promises the ability to deliver an optimal treatment in response to daily patient anatomic variation. A major technical barrier for the clinical implementation of online ART is the requirement of rapid image segmentation. Deformable image registration (DIR) has been used as an automated segmentation method to transfer tumor/organ contours from the plannin...

متن کامل

Implementation and evaluation of various demons deformable image registration algorithms on GPU

Department of Radiation Oncology, University of California San Diego, La Jolla, CA 92037, USA Department of Imaging Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX 77030, USA 10 Department of Radiation Oncology, School of Medicine, Washington University of St. Louis, 4921 Parkview Place, LL, St. Louis, MO 63110, USA San Diego Supercomputer Center, University of California...

متن کامل

A Deformable Image Registration Algorithm Using NURBS

Non-rigid image registration is an interesting and challenging research work in medical image processing, computer vision and remote sensing fields. In order to increase the registration accuracy, this paper designs a composite registration algorithm of a rigid transform and free form deformation. Because NURBS (Non-uniform Rational B Spline) with a non-uniform grid has a higher registration pr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 5

صفحات  559- 568

تاریخ انتشار 2019-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023