A Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma
نویسندگان
چکیده مقاله:
Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten the time of sample preparation considerably. Furthermore, the method was applied in bioequivalence study of new formulations of clomipramine in comparison with reference tablets. The drug and internal standard were extracted from plasma with heptan : isoamyl alcohol (95:5) and re-extracted with 200 ?L of orthophosphoric acid (0.3% v/v). The organic layer was discharged and analysis was performed on C8 reverse phase ODS2 HPLC column with a mobile phase, acetonitrile : water (75:25) and UV detection set at 215 nm. Additionally, a single dose study was carried out with a two-sequence, crossover block-randomized design for bioequivalence study. Clomipramine tablets (3 × 25 mg) of either formulations (reference or test products) were administered separately in two occasions to 12 fasting healthy male volunteers. Blood samples were taken prior to and at 9 points within 48 h after dose administration. The retention time of internal standard (cisapride), clomipramine, and desmethyl clomipramine were 5.6 ± 0.2, 10.3 ± 0.3, and 9.5 ± 0.3 min, respectively. The standard curve covering the concentration ranges of 2.5-120 ng/mL was linear (r2 = 0.9950 and 0.9979) for clomipramine and desmethyl clomipramine. The co-efficient of variation for intra-day and inter-day accuracy and precision was less than 18.3%. The pharmacokinetic parameters Cmax and Tmax were obtained directly from plasma clomipramine concentrations. Kel was estimated by log-linear regression and AUC was calculated by the linear trapezoidal rule. The pharmacokinetic parameters AUC and Cmax were tested for equivalence after log-transformation of data. The 90% standard confidence intervals of the mean values for the test/reference ratios, AUC, and Cmax were within the acceptable bioequivalence limits of 0.80-1.20. These results indicated that the analytical method was linear and accurate. Test and reference formulations were found to be bioequivalent and therefore interchangeable.
منابع مشابه
a simple sample preparation with hplc-uv method for estimation of clomipramine from plasma
clomipramine is a tricyclic antidepressant. different methods for determination of clomipramine hydrochloride in plasma have been described. most of these procedures favor the use of acidic back-extraction in extraction procedure and hplc as the analytical technique. in this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten t...
متن کاملA Simple Sample Preparation with HPLC–UV Method for Estimation of Amlodipine from Plasma: Application to Bioequivalence Study
A simple, rapid and selective method was developed for the estimation of amlodipine from human plasma. The method involves a simple protein precipitation techniques using nifedipine as internal standard. Chromatographic separation was carried out on a reverse phase C18 column using mixture of 50 mM potassium di hydrogen ortho phosphate (pH 7.5) and acetonitrile (60:40, v/v) at a flow rate of 1....
متن کاملA simple HPLC-UV method for the determination of ciprofloxacin in human plasma.
A rapid and sensitive HPLC-UV method for the determination of ciprofloxacin in human plasma is described. Protein precipitation with acetonitrile was used to separate the drug from plasma protein. An ACE(®) 5 C18 column (250 mm×4.6 mm, 5 μm) with an isocratic mobile phase consisting of phosphate buffer (pH 2.7) and acetonitrile (77:23, v/v) was used for separation. The UV detector was set at 27...
متن کاملA Highly Sensitive Hplc Method with Non-extractive Sample Preparation and Uv Detection for Trace Determination of Cinacalcet in Human Plasma
A highly sensitive HPLC method with non-extractive sample preparation and UV detection has been developed and validated for the trace determination of cinacalcet (CIN) in human plasma. Paracetamol (PCM) was used as the internal standard. CIN and PCM were isolated from plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved in isocratic mode on a C18 column (15...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره Volume 9 شماره Number 3
صفحات 243- 250
تاریخ انتشار 2010-11-20
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023