A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
نویسندگان
چکیده مقاله:
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a quality assurance program for dosimetry purposes. Materials and Methods: An amorphous silicon (a-Si) imager (OptiVue500) was used. A low contrast resolution phantom and an image quality phantom were constructed and implemented. Low contrast resolution of the EPID was evaluated by counting the number of holes detectable in the image of phantom using human observers and a software. The image quality phantom was used for modulation transfer function, contrast to noise ratio and noise level evaluations. This phantom contains five sets of high-contrast rectangular bar patterns of variable spatial frequencies and six uniform regions. Results: Although the manual low contrast resolution method was observer-dependent and insensitive to artifacts, the automatic method was robust and fully objective but sensitive to artifacts. The critical frequency values for 6 and 18 MV were 0.3558±0.006 lp/mm and 0.2707±0.006 lp/mm respectively. The contrast-to-noise ratio was found to be ~ 240% higher for 6 MV compared to 18 MV. Conclusion: The developed phantoms provide a convenient process for periodic performance of an EPID. These phantoms are independent of the EPID system and provide robust tools for continuous monitoring of image quality parameters as well as dosimetric parameters.
منابع مشابه
a quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
background: electronic portal imaging devices (epids) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. a successful utilization of epids for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. in this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملA quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radia on therapy portal imaging, geometric and dosimetric verifica ons. A successful u liza on of EPIDs for imaging and dosimetric purposes requires a reliable quality control process rou ne to be carried out regularly. In this study, two in‐house phantoms were developed and analyzed for implementa on in a quality a...
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملAn investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.
The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x 5 cm2 to 20 x 20 cm2 and beam energies of 6 to 18 MV. Coefficients in the mapp...
متن کاملUse of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensity modulated radiotherapy which requires more frequent checking and finer posi...
متن کاملAccuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)
Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 12 شماره None
صفحات 257- 264
تاریخ انتشار 2014-07
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023