A Numerical Investigation of the Time Reversal Mirror Technique for Trans-skull Brain Cancer Ultrasound Surgery
نویسندگان
چکیده مقاله:
Introduction: The medical applications of ultrasound on human brain are highly limited by the phase and amplitude aberrations induced by the heterogeneities of the skull. However, it has been shown that time reversing coupled with amplitude compensation can overcome these aberrations. In this work, a model for 2D simulation of the time reversal mirror technique is proposed to study the possibility of targeting any point within the brain without the need for craniotomy and to calculate the acoustic pressure field and the resulting temperature distribution within the skull and brain during a High Intensity Focused Ultrasound (HIFU) transcranial therapy. Materials and Methods: To overcome the sensitivity of the wave pattern to the heterogeneous geometry of the skull, a real MRI derived 2D model is constructed. The model should include the real geometry of brain and skull. The model should also include the couplant medium which has the responsibility of coupling the transducer to the skull for the penetration of ultrasound. The clinical substance used as the couplant is water. The acoustic and thermal parameters are derived from the references. Next, the wave propagation through the skull is computed based on the Helmholtz equation, with a 2D finite element analysis. The acoustic simulation is combined with a 2D thermal diffusion analysis based on Pennes Bioheat equation and the temperature elevation inside the skull and brain is computed. The numerical simulations were performed using the FEMLAB 3.2 software on a PC having 8 GB RAM and a 2.4 MHz dual CPU. Results: It is seen that the ultrasonic waves are exactly focalized at the location where the hydrophone has been previously implanted. There is no penetration into the sinuses and the waves are reflected from their surface because of the high discrepancy between the speed of sound in bone and air. Under the focal pressure of 2.5 MPa and after 4 seconds of sonication the temperature at the focus reached 51 °C and the temperature of the pre-target bone increased to 56.31 °C. In the post-target region the temperature of the sphenoid bone increased to 47.1 °C while the temperature of the occipital bones reached up to 46 °C. It is also shown that by using a cold water cooling system and cooling down the pre-target bones to 20 °C before sonication, the maximum pre-target bone temperature will not exceed 40 °C and hence the pre-target bone cells will remain intact. Discussion and Conclusion: In this study, it is well demonstrated that by using the time reversal mirror technique it is possible to target any point within the skull without the need for craniotomy. Although at higher acoustic frequencies compared to the lower ones such as 300 kHz the ultrasound undergoes more severe aberrations while passing through media having geometrical heterogeneity and discrepant sound velocities, the simulations performed in this work show that even at such frequencies it is still possible to correct these aberrations using the time reversal mirror technique. The thermal simulations show that by using this method the temperature of the deep seated tumors can be increased to cytotoxic temperature in a few seconds.
منابع مشابه
a numerical investigation of the time reversal mirror technique for trans-skull brain cancer ultrasound surgery
introduction: the medical applications of ultrasound on human brain are highly limited by the phase and amplitude aberrations induced by the heterogeneities of the skull. however, it has been shown that time reversing coupled with amplitude compensation can overcome these aberrations. in this work, a model for 2d simulation of the time reversal mirror technique is proposed to study the possibil...
متن کاملa time-series analysis of the demand for life insurance in iran
با توجه به تجزیه و تحلیل داده ها ما دریافتیم که سطح درامد و تعداد نمایندگیها باتقاضای بیمه عمر رابطه مستقیم دارند و نرخ بهره و بار تکفل با تقاضای بیمه عمر رابطه عکس دارند
Investigation of a large-area phased array for focused ultrasound surgery through the skull.
Non-invasive treatment of brain disorders using ultrasound would require a transducer array that can propagate ultrasound through the skull and still produce sufficient acoustic pressure at a specific location within the brain. Additionally, the array must not cause excessive heating near the skull or in other regions of the brain. A hemisphere-shaped transducer is proposed which disperses the ...
متن کاملAdaptive time-reversal mirror.
The time-reversal mirror uses the received signal from a probe source to refocus the signal at the probe source location by backpropagating the time-reversed version of the received signal. In this study, an adaptive method is described to steer a null to an arbitrary position in a waveguide while maintaining a distortionless response at the probe source location. As an application, selective f...
متن کاملthe algorithm for solving the inverse numerical range problem
برد عددی ماتریس مربعی a را با w(a) نشان داده و به این صورت تعریف می کنیم w(a)={x8ax:x ?s1} ، که در آن s1 گوی واحد است. در سال 2009، راسل کاردن مساله برد عددی معکوس را به این صورت مطرح کرده است : برای نقطه z?w(a)، بردار x?s1 را به گونه ای می یابیم که z=x*ax، در این پایان نامه ، الگوریتمی برای حل مساله برد عددی معکوس ارانه می دهیم.
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 4 شماره Issue 1,2
صفحات 41- 50
تاریخ انتشار 2007-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023