A new method based on fuzzy system and gravitational optimal detector for capacitor placement, considering nonlinear loads

نویسندگان

  • Hossein Dehghan Dehnavi Department of Electrical Engineering, Shahid Beheshti University,Tehran, Iran.
  • Mohammad Shafiyi Department of Electrical Engineering, Shahid Beheshti University,Tehran, Iran.
  • Yaghoub Azizi Department of Electrical Engineering, Shahid Beheshti University,Tehran, Iran.
چکیده مقاله:

This paper describes an advantageous method for using the capacitor banks in the distribution network, optimally. The aim is to determine the count, location and capacitor values in order to minimize the annual cost resulting from energy losses and capacitor bank’s installation cost. Besides, in the case of having nonlinear loads in the network, by installing capacitors in appropriate locations, the possibility of occurring a resonance at harmonic frequencies originating from nonlinear loads, could be reduced. Therefore, in capacitor placement, power quality constraints, including the maximum harmonic deviation value, are taken into account. The case study is a nonlinear problem that a new algorithm based on the gravitational optimal detector and fuzzy system has been used to solve it. In comparison with other intelligent search methods, the proposed algorithm has appropriate precision and convergence rate. The proposed method has been performed on a 69-buss network and a part of the distribution network of city YAZD, and the results confirmed the performance and efficiency of the proposed algorithm.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a new method based on fuzzy system and gravitational optimal detector for capacitor placement, considering nonlinear loads

this paper describes an advantageous method for using the capacitor banks in the distribution network, optimally. the aim is to determine the count, location and capacitor values in order to minimize the annual cost resulting from energy losses and capacitor bank’s installation cost. besides, in the case of having nonlinear loads in the network, by installing capacitors in appropriate locations...

متن کامل

Presenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units

In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...

متن کامل

presenting a new method based on branch placement for optimal placement of phasor measurement units

in this paper, a new method based on branch placement for the optimal positioning of phasor measurement units (pmus) in power systems is proposed. in this method, the pmus are in type of single-channel and are installed at the beginning of the branches. therefore, they are able to measure the bus voltages. also, the installation of the pmus on the branches increases the security of observabilit...

متن کامل

Optimal Placement of Capacitor Banks Using a New Modified Version of Teaching-Learning- Based Optimization Algorithm

Meta-heuristics optimization methods are important techniques for optimal design of the engineering systems. Numerous methods, inspired by different nature phenomena, have been introduced in the literature. A new modified version of Teaching-Learning-Based Optimization (TLBO) Algorithm is introduced in this paper. TLBO, as a parameter free algorithm, is based on the learning procedure of studen...

متن کامل

A new fuzzy based solution of the capacitor placement problem in radial distribution system

A fuzzy based method has been proposed for identification of probable capacitor nodes of radial distribution system. Simulated annealing technique has been used for final selection of the capacitor sizes. New fuzzy membership functions have been formulated where the active power membership is an exponential function of the nodal per unit active power and branch active power loss, the reactive m...

متن کامل

OPTIMAL SENSOR PLACEMENT FOR DAMAGE DETECTION BASED ON A NEW GEOMETRICAL VIEWPOINT

In this study, efficient methods for optimal sensor placement (OSP) based on a new geometrical viewpoint for damage detection in structures is presented. The purpose is to minimize the effects of noise on the damage detection process. In the geometrical viewpoint, a sensor location is equivalent to projecting the elliptical noise on to a face of response space which is corresponding to the sens...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 03  شماره 04

صفحات  199- 207

تاریخ انتشار 2014-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023