A New Load-Flow Method in Distribution Networks based on an Approximation Voltage-Dependent Load model in Extensive Presence of Distributed Generation Sources

نویسندگان

  • Behrooz Vahidi Department of Electrical Eng., Amirkabir University of Technology
  • Hossein Ahmadi Department of Electrical Engineering, Amirkabir University of Technology
چکیده مقاله:

Power-flow (PF) solution is a basic and powerful tool in power system analysis. Distribution networks (DNs), compared to transmission systems, have many fundamental distinctions that cause the conventional PF to be ineffective on these networks. This paper presents a new fast and efficient PF method which provides all different models of Distributed Generations (DGs) and their operational modes (P-V and P-Q nodes) in DNs. This study uses voltage-dependent load model instead of traditional load model (constant P-Q) which is modelled as the combination of a current source in parallel with a constant admittance. This kind of load model is closer to reality and makes the power-flow equations closer to linear conditions. To calculate the angles of the P-V buses, the numerical method (Newton-Raphson method) is applied by separating the PF equations for P-V and P-Q buses. Considering a series of approximations on the angles of these buses, the non-diagonal elements of the Jacobin matrix in Newton-Raphson method are fixed. Hence, the proposed numerical method converges toward an appropriate response in a very low number of iterations and high speed. The voltages of other buses (P-Q buses) are calculated linearly without needing any numerical methods. The presented method proves to be robust and reliable against reconfigured structures and meshed networks. Simulations have been carried out on 14-, 33- and 70-node IEEE test systems and large scale networks such as 6118-buses. The results show that the proposed method is at least 100 and 10 times faster than Gauss-Seidel and Newton-Raphson methods, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Improved Under-Frequency Load Shedding Scheme in Distribution Networks with Distributed Generation

When a distribution network consisting of Distributed Generations (DGs) is disconnected from upstream network, the system may be exposed to severe power imbalance. In order to prevent the damage of power plants, frequency relays operate and remove DGs from the network. In contrast to traditional methods, the main objective in new methods is to keep DG units in service in the islanded distributi...

متن کامل

Analysis and Comparison of Load Flow Methods for Distribution Networks Considering Distributed Generation

Conventional passive distribution networks are changing to modern active distribution networks which are not radial. Conventional load flow methods should be modified for new distribution networks analysis. In modern distribution networks distributed generation (DG) units are embedded with conventional and/or renewable resources. DG units are generally modeled as PV or PQ nodes which inject ...

متن کامل

The Effect of High Penetration Level of Distributed Generation Sources on Voltage Stability Analysis in Unbalanced Distribution Systems Considering Load Model

Static voltage stability is considered as one of the main issues for primary identification before voltage collapsing in distribution systems. Although, the optimum siting of distributed generation resources in distribution electricity network can play a significant role in voltage stability improving and losses reduction, the high penetration level of them can lead to reduction in the improvem...

متن کامل

A New Algorithm for Load Flow Analysis in Autonomous Networks

In this paper, a novel algorithm for the load flow analysis problem in an islanded microgrid is proposed. The problem is modeled without any slack bus by considering the steady state frequency as one of the load flow variables. To model different control modes of DGs, such as droop, PV and PQ, in an islanded microgrid, a new formula for load flow equations is proposed. A hybrid optimization alg...

متن کامل

analysis and comparison of load flow methods for distribution networks considering distributed generation

conventional passive distribution networks are changing to modern active distribution networks which are not radial. conventional load flow methods should be modified for new distribution networks analysis. in modern distribution networks distributed generation (dg) units are embedded with conventional and/or renewable resources. dg units are generally modeled as pv or pq nodes which inject ...

متن کامل

an improved under-frequency load shedding scheme in distribution networks with distributed generation

when a distribution network consisting of distributed generations (dgs) is disconnected from upstream network, the system may be exposed to severe power imbalance. in order to prevent the damage of power plants, frequency relays operate and remove dgs from the network. in contrast to traditional methods, the main objective in new methods is to keep dg units in service in the islanded distributi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 52  شماره 2

صفحات  1- 1

تاریخ انتشار 2020-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.