A New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to150 kHz

نویسندگان

  • F. Zare Power Engineering Group, University of Queensland, Queensland, Australia
  • H. Hassanpour Image Processing and Data Mining Lab, Shahrood University of Technology, Shahrood, Iran
  • M. M. AlyanNezhadi Image Processing and Data Mining Lab, Shahrood University of Technology, Shahrood, Iran
چکیده مقاله:

Grid impedance estimation is used in many power system applications such as grid connected renewable energy systems and power quality analysis of smart grids. The grid impedance estimation techniques based on signal injection uses Ohm’s law for the estimation. In these methods, one or several signal(s) is (are) injected to Point of Common Coupling (PCC). Then the current through and voltage of PCC are measured. Finally, the impedance is assumed as ratio of voltage to current signals in frequency domain. In a noisy system, energy of the injected signal must be sufficient for an accurate approximation. However, power quality issues and regulations limit the energy and the voltage levels of the injected signal. There are three main issues in impedance estimation using signal injection: I) Power quality of grid, II) frequency range of estimation, and finally III) accuracy of estimation. In this paper, the stationary wavelet denoising algorithm is employed instead of increasing the energy of injection signal(s). In the paper, a novel method is proposed for impedance estimation based on selecting several appropriate injection signals and denoising the measured signals. The proposed method is able to impedance estimation in a wide frequency range without any effect on power quality. Finally, simulation results have been carried out to validate the proposed method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grid Impedance Estimation Using Several Short-Term Low Power Signal Injections

In this paper, a signal processing method is proposed to estimate the low and high-frequency impedances of power systems using several short-term low power signal injections for a frequency range of 0-150 kHz. This frequency range is very important, and thusso it is considered in the analysis of power quality issues of smart grids. The impedance estimation is used in many power system applicati...

متن کامل

The Calibration of Hydrophones by a Novel Optical Technique in the Frequency Range 10 Khz to 600 Khz

This paper presents a technique for the absolute calibration of hydrophones using a novel optical method. The method uses a thin, optically reflecting membrane suspended in the acoustic field to allow optical measurement of the acoustic particle velocity using a Doppler interferometer. The hydrophone under test is then substituted for the pellicle, and the hydrophone response to the known acous...

متن کامل

A new technique for bearing fault detection in the time-frequency domain

This paper presents a new Fast Kurtogram Method in the time-frequency domain using novel types of statistical features instead of the kurtosis. For this study, the problem of four classes for Bearing Fault Detection is investigated using various statistical features. This research is conducted in four stages. At first, the stability of each feature for each fault mode is investigated. Then, res...

متن کامل

Two efficient methods for measuring hydrophone frequency response in the 100 kHz to 2 MHz range

As new medical applications of ultrasound emerge with operating frequencies in the hundreds of kilohertz to low megahertz region, it becomes more important to have convenient calibration methods for hydrophones in this frequency range. Furthermore, short diagnostic ultrasound pulses affected by finite amplitude distortion require that the hydrophone frequency response be known well below the ce...

متن کامل

a new microwave shield preparation for super high frequency range: occupational approach to radiation protection

background : widespread use of x-band frequency (a part of the super high frequency microwave) in the various workplaces would contribute to occupational exposure with potential of adverse health effects.  according to limited study on microwave shielding for the workplace, this study tried to prepare a new microwave shielding for this purpose. methods: we used ei-403 epoxy thermosetting resin ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 31  شماره 10

صفحات  1666- 1674

تاریخ انتشار 2018-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023