A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
نویسندگان
چکیده مقاله:
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators with only electronics portal imaging device (EPID) device, the use of this technology for megavoltage cone-beam computed tomography (MV-CBCT) imaging in such cases as urgent palliative radiotherapy treatments, leads to precise localization of the tumor and increases the accuracy of the beam sent to the target area. Since MV-CBCT imaging is possible using EPID, this study is aimed at conducting MV-CBCT and investigating the possibility of using these images in the treatment planning of the radiation therapy. Materials and Methods: Initially, the projection data of an anthropomorphic head phantom was acquired at 3o increments for a 360° of gantry rotation around the patient, and then the 2D projections were reconstructed with Feldkamp cone-beam algorithm. The intensity-to- electron-density calibration was performed for MV-CBCT images to converts the reconstructed gray-level intensity of each image voxel into an electron density value. The reconstructed MV-CBCT images were sent to the treatment planning software, and after the registration with KVCT images, two independent plans were generated on the both CT datasets. Finally, the dose volume histogram (DVH) of the anatomical targets contoured with MV-CBCT was compared to DVH of the same targets contoured with KVCT images. Results: There was a high level of agreement between the MV-CBCT and KVCT plans with the anatomical structures of the skull as the target. The shift between the co-ordinate positions of the anatomical points identified on the MV-CBCT from the reference planning CT points, and the calculated dose based on the both CT datasets have an acceptable level of agreement. Conclusion: The results of this study show that MV-CBCT images could be effective for treatment planning modality include single fraction palliative treatment. However, low contrast resolution and extended scan acquisition time are the two main limiting factor that eliminate this imaging modality only for palliative treatments at easily distinguishable area, such as brain.
منابع مشابه
Feasibility of MV CBCT‐based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT‐based dose calculations
Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image-based treatments that lag behind technical capabilities available for nonurgent radiotherapy. We have developed a novel integrated urgent workflow that uses onboard MV CBCT imaging for patient simulation to improve planning accuracy ...
متن کاملAssessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments
A clinical workflow was developed for urgent palliative radiotherapy treatments that integrates patient simulation, planning, quality assurance, and treatment in one 30-minute session. This has been successfully tested and implemented clinically on a linac with MV CBCT capabilities. To make this approach available to all clin-ics equipped with common imaging systems, dose calculation accuracy b...
متن کاملA Feasibility Study on the Use of TomoTherapy Megavoltage Computed Tomography Images for Palliative Patient Treatment Planning
Dedicated rapid access palliative radiation therapy improves patients' access to care, allowing more timely treatment which would positively impact on quality of life. The TomoTherapy (Accuray, Sunnyvale, CA) system provides megavoltage (MV) fan-beam computed tomography (FBCT) as the image guidance technique, and a module called "statRT" that allows the use of these MV FBCT images for direct pl...
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
a study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولthe effect of consciousness raising (c-r) on the reduction of translational errors: a case study
در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 68- 68
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023