3-D RF Coil Design Considerations for MRI

نویسندگان

  • Babak Ganji Department of Electrical Engineering, Kashan University, Kashan, Iran
چکیده مقاله:

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by electromagnetic coupling. Thus, it is essential to analyze the self and mutual inductances of this coil. Other parameters, including electromagnetic shielding, frequency, and distance, which influence voltage and power transfer are investigated here. Theoretical formulas and simulation models proposed in the present paper are implemented by using MATLAB and ANSYS MAXWELL and ANSYS SIMPLORER Finite Element (FE) packages for determining the performance and properties of the coil. So, the main goal is evaluating of software steps that simplify the design of RF resonance circuits. Also, experimental results are given for the validation of the proposed method. Consequently, Safety and efficiency are automatically maximized by following the best design considerations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

RF Coil Technology for Small-Animal MRI

A review of the theory, technology, and practice of RF coils for small-animal MRI is presented that includes a brief overview of MR S/N analysis and discussions of the various coils commonly used in small-animal MR – surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid-range coils – coils where the product (fd) of the frequency f and the coil diamete...

متن کامل

RF System Design Considerations

Highly integrated and advanced radio designs available today enable the engineer to design RF systems with greater levels of performance than ever before. Recent advancements in the areas of blocking, sensitivity, frequency control and baseband processing are influencing RF system architecture design. The purpose of this article is to explore some of these parametric attributes and consider the...

متن کامل

HTS tape RF coil for low field MRI

M. C. Cheng, K. H. Lee, K. C. Chan, K. K. Wong, E. S. Yang HKU Jockey Club MRI Engineering Center, Hong Kong, Hong Kong, China, People's Republic of Abstract A 5-inch RF receiving coil for 0.21T MRI system was developed using multifilament Bi-2223 High Temperature Superconducting (HTS) tape. The coil was designed to enclose the imaging sample so as to enhance the filling factor and field-of-vie...

متن کامل

Tailored RF Pulse Design for 7T MRI

The primary concern of this thesis is in the design of RadioFrequency (RF) Pulses to be used for Ultra-High Field Magnetic Resonance Imaging. A movement towards higher magnetic field strength has noted advantages. In particular, increased Signal to Noise Ratio (SNR) with increasing field strength. However higher field strength also poses difficult problems, as a result of increasing inhomogenei...

متن کامل

RF Coil Loading Measurements Between 1 and 50 MHz to Guide Field-Cycled MRI System Design

Conventional magnetic resonance imaging (MRI) uses a single superconducting magnet both to polarize the nuclear magnetic moments in a sample and to provide the magnetic field environment under which an image is acquired. In field-cycled MRI (FCMRI), these two tasks are independently accomplished by two actively controlled resistive magnets. As a result, the expressions for signal-to-noise ratio...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 2

صفحات  139- 148

تاریخ انتشار 2017-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023