مقایسه میزان دز جذبی پستان در دستگاه ماموگرافی معمولی و دیجیتال در شرایط مورد استفاده دستگاهها در تبریز
نویسندگان
چکیده مقاله:
Background: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography for breast cancer screening is a controversial subject. This research was done to compare the breast absorbed dose in the conventional and digital mammography devices that used in mammography centers in Tabriz city on 1395. Methods: This research was done as descriptive study. In the first three mammograms, according to the instructions of the Atomic Energy Organization of Iran (AEOI) for quality control were tested. Information about 322 patients who for mammography went to four centers over four months were collected, then the values of average dose of mammary glands in the mammogram images as milli-Gray (mGy) were calculated and analyzed. Results: In the 4 clinics, the mean values of compressed tissue thickness in the conventional mammography device for CC and MLO were 4.01 ± 0.92 cm and 4.49 ± 1.63 cm and the dose values were 1.53 ± 0.58 mGy and 1.58 ± 0.59 mGy respectively, P-value that received is 1. Also the mean values of compressed tissue thickness in digital mammography device for CC and MLO were 5.8 ± 1.00 cm and 6.30 ± 1.01 cm and the dose values 2.07 ± 0.71 mGy and 2.15 ± 0.69 mGy were obtained respectively and also p-value is received 0.925. Conclusion: According to this study, it seems that despite the benefits of digital mammography on the conventional mammography, digital mammography device has more average absorbed dose rather than conventional mammography device. Due to the higher absorbed dose, doing of regular quality control and dose reduction techniques are recommended in digital mammography.
منابع مشابه
اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملDegenerate Four Wave Mixing in Photonic Crystal Fibers
In this study, Four Wave Mixing (FWM) characteristics in photonic crystal fibers are investigated. The effect of channel spacing, phase mismatching, and fiber length on FWM efficiency have been studied. The variation of idler frequency which obtained by this technique with pumping and signal wavelengths has been discussed. The effect of fiber dispersion has been taken into account; we obtain th...
متن کاملمقایسه دوز جذبی دو دستگاه CBCT با رادیوگرافیهای دیجیتال خارج و داخل دهانی در ارگانهای هدف
سابقه و هدف: امروزه جهت رسیدن به طرح درمان جامع و تشخیص صحیح، تجویز رادیوگرافی به تعداد مناسب از یک طرف و حفظ اصول حفاظت بیماران در برابر اشعه غیر ضروری چالش بزرگ پیش روی دندانپزشکان میباشد این مهم در درمانهای جامعی چون ارتودنسی و جراحی های بازسازی ناحیه فک و صورت اهمیت بیشتری پیدا می کند. لذا اندازه گیری مقادیر دوز دریافتی ارگان های حیاتی حین تصویر برداریهای مختلف دندانپزشکی و مقایسه آنها ...
متن کاملبررسی اثربخشی ماموگرافی دیجیتال در مقایسه با ماموگرافی آنالوگ درغربالگری و تشخیص سرطان پستان: مرور سیستماتیک و متاآنالیز
زمینه و هدف: سرطان پستان اولین سرطان شایع و یکی از علل عمده مرگ و میر در بین زنان ایرانی به ویژه درسنین باروری به شمار می رود. ماموگرافی متداول ترین آزمایش غربالگری و تشخیص سرطان پستان است. در حالی که ماموگرافی آنالوگ یک روش استاندارد در غربالگری سرطان پستان است، ماموگرافی دیجیتال می تواند یک روش جایگزین باشد. این مطالعه به مقایسه اثربخشی ماموگرافی دیجیتال و ماموگرافی آنالوگ درتشخیص سرطان پستان...
متن کاملمقایسه تاثیر دو ترکیب هدف- فیلتر مختلف در میزان دوز جذبی پستان در ماموگرافی و بررسی عوامل موثر بر آن به کمک کد MCNPX
ماموگرافی با اشعه x یکی از روشهای پرکاربرد در تشخیص سرطان پستان میباشد. به دلیل حساسیت بافت پستان، میزان دُز دریافتی بیمار در ماموگرافی اهمیت ویژهای دارد. هدف از مطالعه حاضر، بررسی عوامل موثر در میزان دُز جذبی و مقایسه میزان دُز دریافتی برای شرایطی که دستگاه ماموگرافی شامل ترکیب هدف-فیلتر Mo-Moیا W-Rh باشد. در این پژوهش، به کمک کد MCNPX، ساختار تیوپ اشعه x دستگاه ماموگرافی شبیه سازی شده و طیف...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 42 شماره 1
صفحات 40- 45
تاریخ انتشار 2018-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023