مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA
نویسندگان
چکیده مقاله:
Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to control hemodynamic condition and prevent pulmonary barotrauma in patients. Besides airway control during CPR, providing airway for ICU patients or those who need intubation during anesthesia may cause damages because of laryngoscopy, and at the same time needs experienced personnel. Therefore, this investigation was undertaken to find a method through which no experienced personnel or laryngoscopy is needed, and besides which, airway resistance and dynamic compliance can be like the common standard methods. Patients & Methods: This clinical trial study was conducted on 34 patients(22 males and 12 females) aged between 16 to 53(33.1 age±12.4) with ASA(type I and II) who were candidates for orthopaedic surgery to reduce aspiration risk and were selected based on randomized simple sampling. In anesthesia by TIVA method(Total drugs which used IV), propofol was used as anesthetic, fentanyl as analgesic and pavolon as relaxant. Pavolon was used because it has least hystamin release and, therefore, has no effect on airway resistance. Airway resistance and dynamic compliance were measured by NICOME and CO2 in expiration. Results: The results were assessed by t-test and Pvalue<0.05 was observed between mean airway resistance in tracheal tube(7.38±1.55) and laryngeal tube(34.35±3.87). There was a significant difference between airway dynamic compliance in laryngeal tube(26.08±4.54) and tracheal tube(44.55±7.06). There was also a significant difference between cardiac output in use of tracheal tube(5.37±0.207) and laryngeal tube(4.605±0.34) which showed cardiac output was lower in laryngeal tube method. Conclusion: Although laryngeal tube is a suitable alternative in difficult intubation or CPR, high airway resistance and low dynamic compliance causes decline in cardiac output and pulmonary damage therefore, it is not a suitable alternative in all cases. 4) Airway Resistance
منابع مشابه
مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(tiva) comparing air way resistance and dynamic compliance of tracheal tube and laryngeal tube in tiva
زمینه و هدف: هدف از انجام این مطالعه مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال، در بیهوشی داخل وریدی کامل می باشد. امروزه کاهش مقاومت راه هوایی و بهبود کمپلیانس دینامیک (به معنای پذیرش ریه های بیمار در مقابل ورود هوا با فشار مثبت ) حین تهویه مکانیکی، خواه در بخش مراقبت های ویژه و خواه در حین بیهوشی عمومی و به خصوص در بیمارانی که دچار مشکلات ریوی هستند، یک ...
متن کاملمقایسه اثر لیدوکائین داخل تراشه با لیدوکائین وریدی بر پاسخهای راه هوایی هنگام خروج لوله تراشه
Background and Aim: Airways responses during extubation can lead to coughing, laryngospasm and hypertension. The aim of this study was to compare the effects of intratracheal and intravenous lidocaine on airway responses and cardiovascular effects during extubation . Materials and Methods: This clinical trail was preformed on sixty 15-60 year old patients undergoing general or gynecologi...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملمقایسه لوله دهانی حلقی کافدار با لوله تراشه در حفظ راه هوائی و تهویه بیماران تحت بیهوشی عمومی با تنفس خودبخودی
Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask...
متن کاملمقایسه اثر لیدوکائین داخل تراشه با لیدوکائین وریدی بر پاسخ های راه هوایی هنگام خروج لوله تراشه
زمینه و هدف: پاسخ های راه هوایی موقع خارج کردن لوله تراشه می تواند منجر به سرفه، لارنگواسپاسم و افزایش فشار خون شود. این مطالعه به منظور مقایسه اثر لیدوکائین وریدی و داخل تراشه بر روی پاسخهای راه هوایی و قلبی- عروقی بیماران هنگام خروج لوله تراشه انجام شد. روش تحقیق: این مطالعه کارآزمایی بالینی بر روی 60 بیمار 15-60 ساله کاندید جراحی عمومی یا زنان که بر اساس طبقهبندی انجمن بیهوشی آمریکا در ...
متن کاملمقایسه اثر استامینوفن وریدی با رمی فنتانیل بر میزان پاسخ راه هوایی به وجود لوله تراشه در حین و پایان بیهوشی در جراحی اندوسکوپیک سینوس
Aims and Background: Airway hyperactivity is one of the most important complications of tracheal extubation. This study was designed to compare the efficacy of intravenous acetaminophen as an alternative to remifentanil on airway response to tracheal tubes during and at the end of anesthesia in functional endoscopic sinus surgery. Methods and materials: This study was conducted as a double blin...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 12 شماره 48
صفحات 143- 147
تاریخ انتشار 2005-09
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023