مقایسه قدرت دستگاه گلوکومتر Accu-chek با Elite در تشخیص دیابت با استفاده از خونریزی متعاقب Probing
نویسندگان
چکیده مقاله:
Abstract Background: Recent studies have assessed the validity of glucometer devices in estimating the glucose level of gingival blood during routine periodontal examination (Bleeding On Probing). The purpose of this study was to evaluate whether blood oozing from gingival tissues during routine periodontal examination can be used for determining glucose levels by comparing it with laboratory measurements and standard glucometer method using two different glucometers. Methods: 50 patients (27 nondiabetic , 23 diabetic mean age 39/6 ± 11 years), with at least on site of adequate bleeding upon probing, participated in this study. At first the F.P.G test was done in the laboratory, Then the patients were referred to dental department . A site with profuse BOP was chosen for glucose determination. After isolating the appropriate site , probing was performed with Williams probe and then the sensitive tip of the strip was exposed to blood Consequently , the amount of blood glucose (G.C.B.G) was estimated by the devices .Diagnosis of diabetes by conventional capillary fingerstick blood (C.B.G) and Gingival crevicular Blood glucose (G.C.B.G) techniques were compared with the standard technique of Fasting Plasma Glucose (FPG) and the positive predictive values and the negative predictive values were measured. Results: The positive predictive value of Accu-chek and Elite glucometers were %100 and the negative predictive values were 93 and 90.6 percent respectively. The values also showed a very high intrapatient correlation. Conclusion: The results suggested that gingival crevicular blood glucose measurements by both devices can provide an acceptable blood sample for diagnosis of diabetes. In addition, this technique is safe and easy to perform in dental office for diabetes mellitus screening, but the negative predictive value of G.C.B.G is not clinically acceptable. KEYWORDS: Diabetes mellitus, Accu-chek glucometer, Elite glucometer, Bleeding on probing.
منابع مشابه
مقایسه قدرت دستگاه گلوکومتر accu-chek با elite در تشخیص دیابت با استفاده از خونریزی متعاقب probing
چکیده سابقه و هدف: بعضی تحقیقات اخیر تایید نموده اند که کارآیی دستگاه های گلوکومتر در اندازه گیری میزان قند خون لثه حین معاینات معمول پریودنتال دارای کاستی هایی است. لذا مطالعه حاضر به منظور تعیین قدرت دستگاه گلوکومتر accu-chek در تشخیص قند خون متعاقب probing در مقایسه با گلوکومتر elite نسبت به روش استاندارد انجام گرفت. روش بررسی: این تحقیق با طراحی تشخیصی (diagnostic) انجام گرفت. 50 بیمار شامل...
متن کاملاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملاندازه گیری گلوکز خون کبوتر با دستگاه گلوکومتر accu-chek active در مقایسه با روش های استاندارد (اتوآنالایزر مدل biotecnica, targa 3000)
اگرچه برای تشخیص و مانیتورینگ بیماری ها در پرندگان آنالیز بیوشیمیایی لازم می باشد، ولی به دلیل حجم کم نمونه خونی که از پرندگان جهت آنالیز به دست می آید تشخیص آزمایشگاهی محدود شده است. در نتیجه روش مناسبی که نیاز به حجم کمی از خون دارد باید به کار گرفته شود. در این تحقیق تعداد30 قطعه کبوتربا سن بالای شش ماه با میانگین وزن 350 گرم(50± گرم) پس از ارزیابی بالینی و خون شناسی و اطمینان از سلامت آن ...
مقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure
کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...
متن کاملToxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters.
ied this possibility by performing the enzymatic assay on controls containing increasing concentrations of ACET in the presence of different therapeutic concentrations of NAC (Fig. 1A). Evidently, NAC concentrations $100 mg/L cause a marked negative bias, reaching total suppression of the reaction in the presence of 10 g/L NAC. In contrast, similar concentrations of NAC have no effect on the AC...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 33 شماره 4
صفحات 228- 234
تاریخ انتشار 2010-02
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023