تأثیر توزیع یکنواخت و غیریکنواخت نانوذرات با اعداد اتمی بالا در حجم تومور بر فاکتور افزایش دوز در براکی تراپی با چشمه ایریدیم-192

نویسندگان

  • عارفیان, سحر دانشگاه علوم پزشکی جندی شاپور اهواز گروه فیزیک پزشکی
چکیده مقاله:

Introduction: Irradiation of loaded tumor with high-Z nanoparticles with low energy photon of 192Ir source during brachytherapy increases absorbed dose of tumor due to increase in possibility of photoelectric phenomena. Therefore, this study aimed to investigate dose enhancement due to nanoparticles (NPs) with different atomic numbers and concentrations as well as effect of NPs distribution (uniform & non- uniform) on dose enhancement. Methods: Dosimetric parameters of HDR-192Ir source (MicroSelectron model) were calculated by MCNP-4C code on the basis of recommendations of AAPM, TG-43. A tumor (1 cm3) loaded with uniform and non-uniform distribution of 7, 18 and 30 mgr/gr of 79Au, 64Gd, 26Fe and 22Ti in water phantom (30×30×30 cm3) was simulated. Results: DEF of 4.7% to 19.4% and 3.3 to 18.6% were calculated respectively for uniform distribution of 79Au and 64Gd with 7 to 30 mgr/gr concentrations. For non-uniform distribution these values were 0.4%to 1.9% and 0.2% to 1.2%, respectively. Increased dose of the peripheral-health tissue due to presence of 2 to 8.5 mgr/gr of 79Au and 64Gd was estimated from 1.3% to 6.5% and 1.1% to 4.2%, respectively. Conclusion: increase of atomic number and concentrations of NPs enhance the absorbed dose due to increased possibility of photoelectric phenomena. Non-uniform distribution of NPs underestimated dose compared to uniform distribution therefore, considering accurate NPs distribution inside the tumor volume is crucial to calculation of dose enhancement. Targeted labeling of NPs for the maximum absorption by tumor and for the minimal penetration into peripheral tissues has potential to increase radiation therapeutic ratio.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر توزیع یکنواخت و غیریکنواخت نانوذرات با اعداد اتمی بالا در حجم تومور بر فاکتور افزایش دوز در براکی تراپی با چشمه ایریدیم-۱۹۲

مقدمه: پرتودهی تومور پر شده با نانوذرات با اعداد اتمی بالا به وسیله فوتون های کم انرژی چشمه ایریدیوم-192 در براکی تراپی، دوز تومور را به دلیل افزایش احتمال رخداد پدیده فوتوالکتریک افزایش خواهد داد. هدف از این مطالعه، بررسی افزایش دوز ناشی از نانوذرات با اعداد اتمی و با غلظت های مختلف و بررسی اثر توزیع نانوذرات (یکنواخت و غیریکنواخت) بر افزایش دوز بود. روش بررسی: پارامترهای دزیمتری چشمه ایریدیوم...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

افزایش دوز ناشی از تزریق نانوذرات طلا، گادلینیوم، آهن و تیتانیوم به تومورهای سرطانی در براکی‌تراپی با چشمه ایریدیم- 192: روش مونت‌کارلو

زمینه و هدف: در برهمکنش­های فوتون با ماده، افزایش عدد اتمی ماده هدف و کاهش انرژی فوتون تابشی جذب فوتوالکتریک را در آن ماده افزایش می­دهد. در مطالعة حاضر فاکتور افزایش دوز (Dose Enhancmenet Factor) تومور پر شده با نانوذرات (Nano Particles) برای براکی­تراپی با چشمه ایریدیم- 192 مطالعه شد. روش بررسی: محاسبات مونت­کارلو برای تعیین افزایش دوز ناشی از چشمه ایری...

متن کامل

بررسی اثر ناهمگنی‌های بافت بر توزیع دوزچشمه ایریدیم-192 در براکی تراپی

زمینه و هدف: اشکال پروتکل انجمن فیزیک پزشکی آمریکا (AAPM, TG43) برای دزیمتری براکی­تراپی این است که اثر وجود ناهمگنی­های بافتی (استخوان، ریه، ...) بر توزیع دوز به­هنگام به­کارگیری پارامترهای دزیمتری حاصله در نرم­افزارهای طراحی درمان در نظر گرفته نمی­شود. هدف از این تحقیق بررسی اختلافات دوز با و بدون وجود این ناهمگنی­ها در براکی­تراپی با چشمه ایریدیم-192 است.  روش ...

متن کامل

بررسی فاکتور افزایش دوز تومور با حضور نانو ذرات مختلف در براکی-تراپی پروستات به‌روش مونت کارلو

زمینه و هدف: یکی از راه‌های درمان پروستات، استفاده از چشمه‌های براکی‌تراپی کم‌انرژی مانند ید-125 است. هدف ما دراین مطالعه، بررسی فاکتور افزایش دوز تومور با حضور نانو ذرات مختلف در براکی‌تراپی پروستات به‌روش مونت کارلو و بررسی اثر حضور نانو ذرات بر منحنی‌های هم دوز در براکی‌تراپی پروستات می‌باشد. مواد و روش‌ها: در این مطالعه، چشمه‌ی براکی‌تراپی ید-125 مدل SL-125/SH-125 با استفاده از کدMCNPX م...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 21  شماره 5

صفحات  587- 598

تاریخ انتشار 2013-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023