بررسی و اندازه‌گیری دز پرتوهای نوترون ثانویه در پرتودرمانی با اشعۀ ایکس پرانرژی در بیمارستان آیت‌الله خوانساری اراک

نویسندگان

چکیده مقاله:

Medical linear accelerators (linacs) are used efficiently in radiation therapy for tumor treatments. In these devices interaction of high energy photons (greater than 7 MeV) with the target, flattening filters, collimators and even body and patients bed produce secondary particles such as neutrons(photo-neutron production). The purpose of this study is measuring the neutrons dose produced in medical linear accelerator Elekta Precise by using monte carlo code MCNPX simulation and comparing them with the experimental results of the TLD-600 and TLD-700 dosimeters The results show that for the TLDs located exactly below the gantry and on the bed (TLD 1), the thermal neutrons dose proportion to the dose of photons incident in simulation calculations is 0.2%, where the experimental value is 0.21% . The discrepancy between the experimental results and the calculation is around 4%, which shows a good agreement.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی و اندازه گیری دز پرتوهای نوترون ثانویه در پرتودرمانی با اشعۀ ایکس پرانرژی در بیمارستان آیت الله خوانساری اراک

امروزه رادیوتراپی با شتاب دهنده های خطی پزشکی پرانرژی، یکی از روش های درمان مؤثر غده های بدخیم به شمار می رود. در این دستگاه ها از برهم کنش های فوتون های پرانرژی (بزرگ تر از mev7) با اجزای سر شتاب دهنده، تخت و حتی بدن بیمار، آلودگی فوتونوترونی تولید می شود. هدف از این مطالعه، اندازه گیری دز نوترون های تولیدشده در دستگاه شتاب دهندۀ پزشکی الکتا مدل precise بیمارستان آیت الله خوانساری اراک با استف...

متن کامل

بررسی میزان دوز ناشی از پرتوهای نوترون ثانویه در پرتودرمانی با اشعه ایکس پر انرژی در بیمارستان آیت ا... خوانساری اراک

رادیوتراپی با شتابدهنده های خطی پزشکی پر انرژی، یکی از روش های درمان موثر بیماری های بدخیم می باشد. در این دستگاه ها از برهمکنش های الکترون فرودی و فوتون های پر انرژی (بزرگتر از mev7) با هدف، فیلتر های تخت کننده، موازی کننده های اولیه و ثانویه(کولیماتورها)، بدن بیمار و دیگر اجزای حفاظ فوتونی، آلودگی نوترونی تولید می شود. با توجه به آنکه انرژی متوسط نوترون های تولید شده درشتابدهنده های خطی، در م...

محاسبه میزان دز پرتوهای ترمزی ناشی از الکترون ها در پرتو درمانی با الکترون در بیمارستان آیت ا...خوانساری اراک

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

محاسبه میزان دز پرتوهای ترمزی ناشی از الکترون ها در پرتو درمانی با الکترون در بیمارستان آیت ا...خوانساری اراک

هنگام پرتودرمانی بیماران با پرتوهای الکترونی، به دلیل برهم کنش الکترون ها با اجزای مختلف سر شتاب دهندۀ خطی، فانتوم یا بدن بیمار، مقداری اشعۀ ایکس ناخواسته تولید می شود، لذا برای محاسبۀ دز آلودگی فوتون ترمزی ناشی از برهم کنش باریکه های الکترونی شتاب دهندۀ خطی پزشکی الکتا precise واقع در بیمارستان آیت الله خوانساری اراک، ابتدا میزان تولید دز پرتوهای ترمزی در انرژی های ۱۰ و mev۱۵ با استفاده از آشک...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 1

صفحات  39- 47

تاریخ انتشار 2015-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023