بررسی مقایسهای دو سیستم Cone Beam CT به لحاظ دقت اندازهگیری خطی محلهای قراردهی ایمپلنت در مندیبل بهصورت In Vitro
نویسندگان
چکیده مقاله:
Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBCT) is a new imaging technique, which is superior to other methods from different aspects. Thus, we aimed to compare the accuracy of two different CBCT systems (i.e., Promax 3D and Newtom 3G) in measuring the anatomic distances in the mandible. Materials and Methods: In this experimental study, six dry mandibles were used for measuring the width and height of mandible in six areas. Also, caliper was used as the gold standard and the distances were marked by barium sulfate as a radiopaque material. Then, the mandibles were scanned with the two CBCT systems, and the distances were measured by two observers (oral and maxillofacial radiologists) under homogenous conditions by using their respective software. The obtained results were evaluated by multivariate ANOVA and compared with the gold standard. Results: The accuracy of both CBCT systems (in all the three FOVs) was close to that of collies in measuring the height of mandible. The accuracy of Promax 3D was closer to collies in evaluating bacco-lingual width, and it was more accurate than Newtom 3G (in all the three FOVs; P<0.001). Thus, the accuracy of Promax system is close to the gold standard in the evaluation of the mandible height and bacco-lingual width. Conclusion: The results of this study showed that Promax 3D and Newtom 3G techniques (in all the three FOVs) have millimeter precision and are capable of measuring the lengths and widths needed to establish the treatment plan.
منابع مشابه
ارزیابی دقت cone beam computed tomography در تعیین عرض ریج آلوئولار بر روی مندیبل خشک
چکیده ندارد.
15 صفحه اولبررسی دقت رادیوگرافی پانورامیک در تعیین ارتباط ریشه دندانهای خلفی فک بالا با سینوس ماگزیلای به کمک Cone-Beam CT
Background and Aims: It is crucial to verify the relationship between root apices and maxillary sinus floor in some surgical procedures like extraction and implant placement or in orthodontic movements like intrusion. Protrusion of roots into the sinus increases the risk of post extraction pneumatization which in turn decreases the available bone at the implant or denture sites. The aim of th...
متن کاملAn in vitro evaluation of cone-beam breast CT methods.
Tomosynthesis was developed for mammography, especially breast cancer detection. However, its limited-angular range scan and resultant data incompleteness causes strong image artifacts and distortions. To address this problem, a hybrid imaging method was proposed in our previous work, which combines tomosynthesis and low-resolution CT into a single system to produce fewer artifacts and distorti...
متن کاملArtefacts in cone beam CT
Cone beam computed tomography (CBCT) is the modern third dimension applied in the field of oral maxillofacial region. With lower radiation dose compared to conventional CT, its applications in dentistry has increased tremendously. Artefacts can seriously degrade the quality of computed tomographic (CBCT) images, sometimes to the point of making them diagnostically unusable. To optimize image qu...
متن کاملبررسی مقایسهای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازهگیری ضایعات استخوانی پریودنتال
Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...
متن کاملPhysics (CT VI-Cone Beam CT)
Participants Kai Niu, MS, Madison, WI (Presenter) Nothing to Disclose Pengfei Yang, Shanghai, China (Abstract Co-Author) Nothing to Disclose Beverly A. Kienitz, MD, DDS, Madison, WI (Abstract Co-Author) Nothing to Disclose Ke Li, PhD, Madison, WI (Abstract Co-Author) Nothing to Disclose Sebastian Schafer, Madison, WI (Abstract Co-Author) Consultant, Siemens AG Kevin Royalty, PhD,MBA, Hoffman Es...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 24 شماره 4
صفحات 345- 351
تاریخ انتشار 2018-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023