بررسی اثر پاشنه آند بر دوز دریافتی بیضهها در رادیوگرافی لگن
نویسندگان
چکیده مقاله:
Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male patients undergoing pelvic radiography. Methods: This is a cross-sectional study, conducted at one of the teaching hospitals of Ahvaz, Jundishapur University of Medical Science Ahvaz, Iran, from September 2015 to March 2016. In order to measure the profile of radiation intensity variation, 13 paired sets of high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD) aligned on the cathode-anode central axis upon the table and then irradiated using routine exposure parameters. The anode of X-ray tube was positioned toward the feet for 40 patients and toward the head for 39 patients undergoing pelvic radiography. For measure the entrance skin dose (ESD), 8 TLD chips were located on the central point of the radiation field and 5 TLDs were located on the testes position to measure the dose received. Results: Radiation intensity profile showed that radiation intensity decrease from the cathode to the anode side. Discrepancy of radiation intensity on central axis of cathode-anode was calculated about 35%. The radiation dose received by the testes was 26.74% lower for patients the anode directed toward the feet, compared to the patients in which the anode directed toward the head (FTC: 1.260±0.296 mGy, FTA: 0.923±0.167 mGy, P<0.05). There was no meaningful difference for the measured ESD of pelvis between two groups of patients (FTC: 1.256±0.315 mGy, FTA: 1.195±0.205 mGy, P=0.788). Conclusion: In pelvic radiography, positioning of testes directed to the anode of X-ray tube can decrease the receive dose.
منابع مشابه
اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملمقایسه دوز اشعه دریافتی تیروئید و عدسی چشم در رادیوگرافی معمولی و رادیوویزیوگرافی
This article presents a comparative clinical study of digital imaging, as a new technology, and conventional method for X - Ray absorption in lens and thyroid.Clinical examination was performed on 50 patients with an average of 28 years among the cases who were reffered to the department of rediology, Islamic Azad universiy of IRAN in 1999.Two pocket dosimeters were used to meausre the dose rat...
متن کاملتاثیر کفش های پاشنه بلند بر لوردوز کمری و راستای لگن در صفحه ساژیتال-مقاله مروری
مقدمه و اهداف با توجه به روند افزایشی استفاده از کفشهای پاشنه بلند در میان زنان، مطالعه بر روی اثرات آن بر روی بدن و به خصوص لوردوز کمری و راستای لگن ضروری به نظر میرسد. مطالعات متعددی در این زمینه انجام شده است، اما در این مطالعات همسویی در مورد اثرات پوشیدن این کفشها به چشم نمیخورد و در برخی موارد حتی تناقض وجود دارد. این تناقضات به خصوص در مورد تاثیر کفش پاشنه بلند بر لوردوز کمری بیشتر...
متن کاملبررسی اثر ناهمگنی بافت در دوز دریافتی پرتوهای اورتو ولتاژ در ناحیه نخاع گردنی موش صحرایی
Background & Aim: The most important physical quantity of irradiation to predict and evaluate the response of biological samples to irradiation is absorbed dose. Recently, according to ICRU(International Commission on Radiation Units and Measurements) reports, determination of absorbed dose with 3.5% accuracy is recommended. Dose distribution is usually estimated in homogeneous mass by unit...
متن کاملمقایسه دوز اشعه دریافتی تیروئید و عدسی چشم در رادیوگرافی معمولی و رادیوویزیوگرافی
با توجه به جدید بودن روش تصویربرداری مستقیم دیجیتال و به منظور مقایسه این روش با روش معمولی از نظر میزان جذب اشعه در عدسی چشم و تیروئید، تحقیق حاضر در سال 78-1377 در بخش رادیولوژی دانشکده دندانپزشکی دانشگاه آزاد اسلامی ایران انجام شد. این تحقیق به روش توصیفی-تحلیلی بر روی 50 نمونه با میانگین سنی 28 سال (از بیمارانی که نیازمند رادیوگرافی سری پری اپیکال بودند)، صورت گرفت. جهت بررسی میزان جذب اشعه...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 75 شماره None
صفحات 113- 119
تاریخ انتشار 2017-05
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023