ارزیابی تغییرات توزیع دز در مقطع نگاری کامپیوتری با تغییر موازی سازی با استفاده از فیلم EBT و فانتوم PMMA

نویسندگان

چکیده مقاله:

X-ray computed tomography is an imaging method which makes tomographic images with high contrast and resolution. However, CT-scans deliver much more radiation dose compared with other imaging techniques. The aim of this study was to evaluate two-dimensional dose distribution in a PMMA phantom as well as investigationof the effect ofcollimation factor on the dose distribution measuredusing GAF-Chromic EBT films. In this study the GAF-Chromic EBT films were cut to the dimensions of 6Í5 cm2 and exposured with different collimations (1, 3, 5, 7, 10 mm), while the other imaging parameters were fixed. After48 h post irradiation the films were reading using Power look 2100XL scanner model at the red channel. Then, the films were analyzed using MATLAB software.The optical density values ​​of each film wereatributed to the related absorbed dose. Image analysis showed that the dose distribution is non-uniform in CT-scan.Results showed that the CTDIvol measured by EBT filmswas more than that of shown on theoperator console. These differences in collimations of 1 mm and 10 mm were 13.5%1.25% and 0.7%1.25% respectively. It was also resulted that the CT dose was decresed withincrease in collimation. In addition, it was observed that the minimum and maximum dose were delivered by using  collimation factor of 10 mm and 1 mm respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی تغییرات توزیع دز در مقطع نگاری کامپیوتری با تغییر موازی سازی با استفاده از فیلم ebt و فانتوم pmma

مقطع نگاری عرضی کامپیوتری(ct-scan) یکی از روش­های تصویربرداری است که در آن با استفاده از پرتو ایکس تصاویر مقطعی از بدن با تباین (کنتراست) و تفکیک پذیری (رزولوشن) بالا به دست می­آید. با این حال پرتودهی ناشی از آزمون­های مقطع نگاری عرضی کامپیوتری نسبت به سایر روش­های تصویربرداری باعث انتقال دز بیشتر به افراد می­شود. هدف از این مطالعه ارزیابی نحوه توزیع دز در یک فانتوم معادل بافتاز جنس پلی متیل مت...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

متن کامل

بررسی عمق نفوذ و توزیع دز الکترون‌های تک‌انرژی در فانتوم گردن با استفاده از کد MCNPX

Penetration and estimation of absorbed dose of electron in soft tissue is investigated in this paper. Neck phantom was simulated by MCNPX code version 2.6. The Phantom was included skin, adipose, neck tissue, neck bone and thyroid glands. Radiation source kept near to the skin surface and located in the back of the neck. Electrons were collided perpendicular to the skin surface. The curves show...

متن کامل

بررسی توزیع دوز در اسکنر ct با استفاده از فانتوم های polymethyl methacrylate (pmma) استوانه ای

مقدمه: هدف از این تحقیق، بررسی تأثیر اندازه ی بیمار بر مقدار و توزیع دوز ct (computed tomography) بر اساس فانتوم های استوانه ای استاندارد پلی متیل متااکریلیک (pmma یا polymethyl methacrylate) بود. روش ها: در این تحقیق، یک روش فیلم دوزیمتری دو بعدی با استفاده از فیلم های رادیوگرافی ارایه شد و با به کارگیری فانتوم هایی با قطرهای 10، 16، 24 و 32 سانتی متر، تأثیر اندازه ی بیمار بر توزیع دوز و میزان...

متن کامل

اندازه گیری دز جذبی الکترون در فانتوم آب به روش تمام نگاری دیجیتال با باریکه لیزر

پرتو­های پرانرژی الکترونی، از جمله پرتوهای یون‌سازی هستند که کاربرد فراوانی در پزشکی هسته­ای و برای درمان تومورهای سرطانی دارند. با این وجود، این پرتوها در طی مسیر خود در بدن بیمار می­توانند به سلول‌های سالم نیز آسیب وارد نمایند. بنابراین، آگاهی از نحوه توزیع دز جذبی در فانتومی معادل با بافت بدن، نیاز اصلی طراحی درمان با استفاده از پرتوهای الکترونی است. در سالیان اخیر استفاده از روش تمام­نگاری ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 3

صفحات  43- 56

تاریخ انتشار 2015-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023